CHERRY HILL, NJ —
OSHA Inspection: AIR DISTRIBUTION SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AIR DISTRIBUTION SYSTEMS, INC. in 1000 ASTORIA BLVD., CHERRY HILL, NJ 08003 (NAICS 332322). OSHA activity number 339616617.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIR DISTRIBUTION SYSTEMS, INC.
- Site address
- 1000 ASTORIA BLVD.
- City
- CHERRY HILL
- State
- NJ
- ZIP
- 08003
- Mailing
- 1000 ASTORIA BLVD., CHERRY HILL, NJ 08003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 55
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C06 I
- Issued
- Apr 11, 2014
- Abate by
- May 7, 2014
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) 1000 Astoria Blvd., Cherry Hill, NJ 08003 - The employer did not conduct at least yearly, an inspection of its lockout/tagout program to determine whether or not authorized employees were following the requirements of the program. On or about 02/25/2014. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
More inspections at AIR Distribution Systems, INC.
View AIR Distribution Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339616617.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.