TYLER, TX —
OSHA Inspection: RAMON RODRIGUEZ
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of RAMON RODRIGUEZ in 1945 WEST SOUTHWEST LOOP 323, TYLER, TX 75701 (NAICS 238160). OSHA activity number 339629750.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAMON RODRIGUEZ
- Site address
- 1945 WEST SOUTHWEST LOOP 323
- City
- TYLER
- State
- TX
- ZIP
- 75701
- Mailing
- 4124 MODLIN STREET, MESQUITE, TX 75150
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.102 A01
- Issued
- Mar 19, 2014
- Abate by
- Mar 27, 2014
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: This violation occurred on or about March 13, 2014, at a job site located at 1945 West Southwest Loop 323, Tyler, Texas 75701, where employees using pneumatic nailers were not protected from eye injuries by wearing protective eyewear.
Recent events (1)
- — Z (S) $2200
1926.501 B11
- Issued
- Mar 19, 2014
- Abate by
- Mar 25, 2014
- Penalty
- Initial $10,780 · Current $10,780
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: This violation occurred on or about March 13, 2014, at a job site located at 1945 West Southwest Loop 323, Tyler, Texas 75701, where employees working on a roof were not protected from falling approximately 30 feet to the ground below. Ramon Rodriguez was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(11), which was contained in OSHA inspection number 316092618, citation number 1, item number 2, and was affirmed as a final order on January 24, 2012, with respect to a workplace located at 10928 Audelia Road, Dallas, Texas 75243.
Recent events (1)
- — Z (R) $10780
More inspections at Ramon Rodriguez
View Ramon Rodriguez's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339629750.