OSHA Inspection: SOUTHWEST DESIGN & LANDSCAPING, LLC

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of SOUTHWEST DESIGN & LANDSCAPING, LLC in CORNER OF CAPITOL STREET AND FARRISH, JACKSON, MS 39269 (NAICS 561730). OSHA activity number 339630170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southwest Design & Landscaping, LLC — free Get an email when a new federal OSHA severe-injury report for Southwest Design & Landscaping, LLC is published. One employer, no account, unsubscribe in one click.
Site address
CORNER OF CAPITOL STREET AND FARRISH
City
JACKSON
State
MS
ZIP
39269
Mailing
2083 HIGHWAY 98 EAST, MCCOMB, MS 39648
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.55 B

Serious Gravity 10 1 instance 1 exposed
Issued
May 30, 2014
Abate by
Jul 3, 2014
Penalty
Initial $2,800 · Current $2,800

Hazardous substances 9010

29 CFR 1926.55(b): Feasible administrative or engineering controls were not implemented to reduce employee exposure to silica.  (a) Capitol Street, Jackson, MS - On or about March 13, 2014 the brick cutter at Southwest Design & Landscaping, LLC was over exposed to total silica dust at a concentration of 1259 mppcf (million particles per cubic foot of air) expressed as an 8 hour time weighted average of approximately 277 times the daily Permissible Exposure Limit (PEL) of 4.55 mppcf based on a 186 minute sampling period; exposure calculations included a zero increment for the time not sampled.
Recent events (1)
  • — Z (S) $2800

1910.134 C01

Serious Gravity 10 1 instance 1 exposed
Issued
May 30, 2014
Abate by
Jun 18, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use.  (a) Capitol Street, Jackson, MS - On or about March 13, 2014 the employer had not established or implemented a written respirator program.
Recent events (1)
  • — Z (S) $0

1910.134 D01 I

Serious Gravity 10 1 instance 1 exposed
Issued
May 30, 2014
Abate by
Jun 18, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability.  (a) Capitol Street, Jackson, MS - On or about March 13, 2014 the employer had not selected the appropriate respirator based on the hazard to the employee.
Recent events (1)
  • — Z (S) $0

1910.134 E01

Serious Gravity 10 1 instance 1 exposed
Issued
May 30, 2014
Abate by
Jun 18, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee�s ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.  (a) Capitol Street, Jackson, MS - On or about March 13, 2014 the employer had not provided medical evaluation before employee began using respirator protection.
Recent events (1)
  • — Z (S) $0

1910.134 F01

Serious Gravity 10 1 instance 1 exposed
Issued
May 30, 2014
Abate by
Jun 18, 2014
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT).   (a) Capitol Street, Jackson,MS - On or about March 13, 2014 the employer had not fit tested the employees for respirator use.