Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: ATLANTA PRECISION METAL FORMING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATLANTA PRECISION METAL FORMING in 3550 ATLANTA INDUSTRIAL PARKWAY NORTHWEST, ATLANTA, GA 30331 (NAICS 336360). OSHA activity number 339636268.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlanta Precision Metal Forming for free Get an email when a new federal OSHA severe-injury report for Atlanta Precision Metal Forming is published. One employer, no account, unsubscribe in one click.
Site address
3550 ATLANTA INDUSTRIAL PARKWAY NORTHWEST
City
ATLANTA
State
GA
ZIP
30331
Mailing
3550 ATLANTA INDUSTRIAL PARKWAY NORTHWEST, ATLANTA, GA 30331
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336360
Employees
135
Ownership type
Private (A)

5 citations on file for this inspection.

1910.146 C02

Serious Gravity 5 1 instance 1 exposed
Issued
May 16, 2014
Abate by
Jul 11, 2014
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:     a. Power Press #35 - The confined space pit beneath the mechanical power press was not marked nor were employees warned by other equally effective measures.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.146 C04

Serious Gravity 5 1 instance 2 exposed
Issued
May 16, 2014
Abate by
Jul 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    a.  Pit below machine #35 - The employer did not develop and implement a permit required confined space program for when employees entered the hazardous space.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
May 16, 2014
Abate by
Jun 5, 2014
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     a.  Press Area, Press #28 - The mounted belt sander used to deburr metal parts, was not covered or guarded thereby exposing employees to rotating parts and ingoing nip points.
Recent events (2)
  • · I (S) $2160
  • · Z (S) $3600

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
May 16, 2014
Abate by
Jun 12, 2014
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     a. Press room, pedestal mounted belt sander - The electrical box and switch was mounted on the side of the motor with a zip tie and not securely fixed to the side of the motor with secure mountings such as bolts thereby exposing employees to shock hazards.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.305 E01

Serious Gravity 1 1 instance 2 exposed
Issued
May 16, 2014
Abate by
Jun 12, 2014
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:    a.  Oil burn off area - The electrical boxes and fittings in the float switch area were not enclosed to prevent moisture, oil and water from entering.
Recent events (2)
  • · I (S) $1620
  • · Z (S) $2700