OSHA Inspection: MITCHELL ELLIS PRODUCTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MITCHELL ELLIS PRODUCTS, INC. in 9086 CHURCH STREET, SEMMES, AL 36575 (NAICS 444220). OSHA activity number 339640799.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mitchell Ellis Products, INC. — free Get an email when a new federal OSHA severe-injury report for Mitchell Ellis Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9086 CHURCH STREET
City
SEMMES
State
AL
ZIP
36575
Mailing
P.O. BOX 628, SEMMES, AL 36575
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444220
Employees
12
Ownership type
A

6 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 30, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  (a)  In the yard:  On March 20, 2014 and at times prior to; the employer failed to train employees that operate the powered industrial trucks exposing the operators and employees working around the trucks to struck-by and crushing hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.178 Q01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 30, 2014
Abate by
Jul 18, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  (a)  At the facility:  On March 20, 2014 and at times prior to; the employer failed to remove powered industrial trucks (PIT) from service that were not in safe operating condition, in that the YALE, PIT had an inoperative back-up alarm exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 30, 2014
Abate by
Jul 18, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:  (a)  South side of east building:  On March 20, 2014 and at times prior to; the employer exposed employees to fire hazards by storing 4 compressed gas oxygen cylinders and 2 acetylene gas cylinders side by side in the storage racks.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 30, 2014
Abate by
Jul 18, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a)  In the Fabrication shop along the west wall: On March 20, 2014 and at times prior to; the employer failed to legibly mark the electrical panels creating an electrical hazard for employees.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 B02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 30, 2014
Abate by
Jul 9, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  (a)  Along the north wall of the compressor room:  On March 20, 2014 and at times prior to; the employer failed to provide a cover for the electrical circuits of the champion compressor, exposing employees working around the compressor to an electrical shock hazard of 480VAC.  (b)  Along the west wall of the fabrication shop:  On March 20, 2014 and at times prior to the employer failed to cover a hole left open by a missing circuit breaker exposing employees working in the to fire hazards.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 H06

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 30, 2014
Abate by
Jul 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(h)(6): Strain relief was not provided at connections and terminations.   (a)  On the west wall in the fabrication shop:  On March 20, 2014 and at times prior to; the employer failed to provide strain relief for connectors in that the conduit was separated from the junction box creating electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Mitchell Ellis Products, INC.'s full OSHA safety record →