SEMMES, AL —
OSHA Inspection: MITCHELL ELLIS PRODUCTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MITCHELL ELLIS PRODUCTS, INC. in 9086 CHURCH STREET, SEMMES, AL 36575 (NAICS 444220). OSHA activity number 339640799.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MITCHELL ELLIS PRODUCTS, INC.
- Site address
- 9086 CHURCH STREET
- City
- SEMMES
- State
- AL
- ZIP
- 36575
- Mailing
- P.O. BOX 628, SEMMES, AL 36575
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444220
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 L01 I
- Issued
- Jun 30, 2014
- Abate by
- Jul 25, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) In the yard: On March 20, 2014 and at times prior to; the employer failed to train employees that operate the powered industrial trucks exposing the operators and employees working around the trucks to struck-by and crushing hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.178 Q01
- Issued
- Jun 30, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: (a) At the facility: On March 20, 2014 and at times prior to; the employer failed to remove powered industrial trucks (PIT) from service that were not in safe operating condition, in that the YALE, PIT had an inoperative back-up alarm exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Jun 30, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: (a) South side of east building: On March 20, 2014 and at times prior to; the employer exposed employees to fire hazards by storing 4 compressed gas oxygen cylinders and 2 acetylene gas cylinders side by side in the storage racks.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.303 F02
- Issued
- Jun 30, 2014
- Abate by
- Jul 18, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) In the Fabrication shop along the west wall: On March 20, 2014 and at times prior to; the employer failed to legibly mark the electrical panels creating an electrical hazard for employees.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.305 B02 I
- Issued
- Jun 30, 2014
- Abate by
- Jul 9, 2014
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) Along the north wall of the compressor room: On March 20, 2014 and at times prior to; the employer failed to provide a cover for the electrical circuits of the champion compressor, exposing employees working around the compressor to an electrical shock hazard of 480VAC. (b) Along the west wall of the fabrication shop: On March 20, 2014 and at times prior to the employer failed to cover a hole left open by a missing circuit breaker exposing employees working in the to fire hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.305 H06
- Issued
- Jun 30, 2014
- Abate by
- Jul 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(h)(6): Strain relief was not provided at connections and terminations. (a) On the west wall in the fabrication shop: On March 20, 2014 and at times prior to; the employer failed to provide strain relief for connectors in that the conduit was separated from the junction box creating electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Mitchell Ellis Products, INC.
View Mitchell Ellis Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 444220)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339640799.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.