Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. FOOD AND DRUG ADMINISTRATION in 1699 EAST CARR RD BLDG. C, CALEXICO, CA 92231 (NAICS 926140). OSHA activity number 339642407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Food and Drug Administration — free Get an email when a new federal OSHA severe-injury report for U.S. Food and Drug Administration is published. One employer, no account, unsubscribe in one click.
Site address
1699 EAST CARR RD BLDG. C
City
CALEXICO
State
CA
ZIP
92231
Mailing
1699 EAST CARR RD. BLDG. C, CALEXICO, CA 92231
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
926140
Employees
4
Ownership type
D

2 citations on file for this inspection.

1910.304 B04 II B

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  Kitchenette/Laboratory - On or about 3/19/2014, and at times prior thereto, total cord and plug-connected loads on a surge protector were in excess of the maximum specified in Table S-4.
Recent events (1)
  • — Z (S) $0

1910.303 G02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 26, 2014
Abate by
Apr 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:  FDA work station adjacent to lobby window - On or about 3/19/14, electrical wiring was not properly guarded from inadvertent contact.