CALEXICO, CA —
OSHA Inspection: U.S. FOOD AND DRUG ADMINISTRATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. FOOD AND DRUG ADMINISTRATION in 1699 EAST CARR RD BLDG. C, CALEXICO, CA 92231 (NAICS 926140). OSHA activity number 339642407.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. FOOD AND DRUG ADMINISTRATION
- Site address
- 1699 EAST CARR RD BLDG. C
- City
- CALEXICO
- State
- CA
- ZIP
- 92231
- Mailing
- 1699 EAST CARR RD. BLDG. C, CALEXICO, CA 92231
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 926140
- Employees
- 4
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.304 B04 II B
- Issued
- Mar 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4: Kitchenette/Laboratory - On or about 3/19/2014, and at times prior thereto, total cord and plug-connected loads on a surge protector were in excess of the maximum specified in Table S-4.
Recent events (1)
- — Z (S) $0
1910.303 G02 II
- Issued
- Mar 26, 2014
- Abate by
- Apr 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: FDA work station adjacent to lobby window - On or about 3/19/14, electrical wiring was not properly guarded from inadvertent contact.
Recent events (1)
- — Z (S) $0
More inspections at U.S. Food and Drug Administration
View U.S. Food and Drug Administration's full OSHA safety record →
More inspections in this industry (NAICS 926140)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339642407.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.