ROME, GA ·
OSHA Inspection: PIRELLI TIRE NORTH AMERICA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PIRELLI TIRE NORTH AMERICA in 100 PIRELLI DRIVE, ROME, GA 30161 (NAICS 326211). OSHA activity number 339642845.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PIRELLI TIRE NORTH AMERICA
- Site address
- 100 PIRELLI DRIVE
- City
- ROME
- State
- GA
- ZIP
- 30161
- Mailing
- 100 PIRELLI DRIVE, ROME, GA 30161
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326211
- Employees
- 10000
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 28, 2014
- Abate by
- Jun 23, 2014
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy: a. Production line 5 - The employer did not develop, document and use energy control procedures to control sources of potential hazardous energy on equipment such as but limited to, the hydraulic lifting mechanisms.
Recent events (2)
- · I (S) $4900
- · Z (S) $7000
1910.332 B01
- Issued
- May 28, 2014
- Abate by
- Jun 23, 2014
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a. Throughout the facility - An employee who worked on or near live electrical parts was not trained in and familiar with electrical safety related work practices thereby exposing the employees to shock and arc flash/blast hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $7000
1910.333 A
- Issued
- May 28, 2014
- Abate by
- Jun 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a. Throughout the facility - When employees were working on or near live electrical equipment safety related work practices were not used, thereby exposing employees to shock and arc flash/blast hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 A01 I
- Issued
- May 28, 2014
- Abate by
- Jun 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a. Throughout the facility - When testing and or maintenance of electrical wires and equipment over 50 Volts was performed in the facility, employees were not provided with nor required to use appropriate electrical protective equipment sufficient for the hazards to which they were exposed thereby exposing the employees to shock and arc flash/blast hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.335 A01 II
- Issued
- May 28, 2014
- Abate by
- Jun 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested: a. Maintenance Department - The electrical protective sleeves and gloves had not been dielectrically tested prior to initial use and had not been tested at the intervals necessary to ensure that the protective factor had been maintained for employee protection, thereby exposing the employees to shock hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Pirelli Tire North America
View Pirelli Tire North America's full OSHA safety record →
More inspections in this industry (NAICS 326211)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339642845.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.