FULTON, NY —
OSHA Inspection: FULTON TOOL CO.,INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FULTON TOOL CO.,INC. in 802 WEST BROADWAY, FULTON, NY 13069 (NAICS 333999). OSHA activity number 339645285.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FULTON TOOL CO.,INC.
- Site address
- 802 WEST BROADWAY
- City
- FULTON
- State
- NY
- ZIP
- 13069
- Mailing
- 802 WEST BROADWAY, FULTON, NY 13069
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 1, 2014
- Abate by
- May 4, 2014
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the lifting device fail: a) Cutting Room, on or about 3/18/14: A CM Shopstar 500 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. b) Cutting Room, on or about 3/18/14: A Chicago 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. c) Cutting Room, on or about 3/18/14: A CM Shopstar 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. d) Main Shop, on or about 3/18/14: A Gantry 1 ton overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. e) Main Shop, on or about 3/18/14: A HSI 750 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. f) Main Shop, on or about 3/18/14: A HSI 750 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. g) Main Shop, on or about 3/18/14: A CM Shopstar 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis. h) Main Shop, on or about 3/18/14: A Chicago 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.303 B02
- Issued
- Apr 1, 2014
- Abate by
- May 4, 2014
- Penalty
- Initial $1,020 · Current $714 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Cutting Room, on or about 3/18/14: Employees using quad metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only. b) Cutting Room, on or about 3/18/14: Employees using a duplex metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only. c) Cutting Room, on or about 3/18/14: Employees using a duplex metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only. d) Main Shop, OKK VP400 Area, on or about 3/18/14: Employees using a quad metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only. e) Main Shop, OKK HM8005 Area, on or about 3/18/14: Employees using a quad metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.
Recent events (2)
- — I (S) $714
- — Z (S) $1020
More inspections at Fulton Tool Co.,Inc.
View Fulton Tool Co.,Inc.'s full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339645285.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.