Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FULTON TOOL CO.,INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FULTON TOOL CO.,INC. in 802 WEST BROADWAY, FULTON, NY 13069 (NAICS 333999). OSHA activity number 339645285.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fulton Tool Co.,Inc. — free Get an email when a new federal OSHA severe-injury report for Fulton Tool Co.,Inc. is published. One employer, no account, unsubscribe in one click.
Site address
802 WEST BROADWAY
City
FULTON
State
NY
ZIP
13069
Mailing
802 WEST BROADWAY, FULTON, NY 13069
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
18
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 1 8 instances 8 exposed
Issued
Apr 1, 2014
Abate by
May 4, 2014
Penalty
Initial $1,200 · Current $840 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by the load should the lifting device fail:  a) Cutting Room, on or about 3/18/14: A CM Shopstar 500 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  b) Cutting Room, on or about 3/18/14: A Chicago 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  c) Cutting Room, on or about 3/18/14: A CM Shopstar 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  d)  Main Shop, on or about 3/18/14: A Gantry 1 ton overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  e) Main Shop, on or about 3/18/14: A HSI 750 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  f) Main Shop, on or about 3/18/14: A HSI 750 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  g) Main Shop, on or about 3/18/14: A CM Shopstar 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.  h) Main Shop, on or about 3/18/14: A Chicago 250 pound overhead hoist being used to move equipment had not been inspected on a frequent and periodic basis.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.303 B02

Serious Gravity 1 5 instances 8 exposed
Issued
Apr 1, 2014
Abate by
May 4, 2014
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Cutting Room, on or about 3/18/14:  Employees using quad metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.  b)  Cutting Room, on or about 3/18/14:  Employees using a duplex metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.  c)  Cutting Room, on or about 3/18/14:  Employees using a duplex metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.  d)  Main Shop, OKK VP400 Area, on or about 3/18/14:  Employees using a quad metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.  e)  Main Shop, OKK HM8005 Area, on or about 3/18/14:  Employees using a quad metal outlet box connected to a flexible cord that was not in accordance with UL approval. Box is listed for permanent mounting only.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

View Fulton Tool Co.,Inc.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339645285.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.