Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MORGAN ENGINEERING SYSTEMS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MORGAN ENGINEERING SYSTEMS INC. in 1182 EAST SUMMIT STREET, ALLIANCE, OH 44601 (NAICS 333923). OSHA activity number 339648925.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morgan Engineering Systems INC. — free Get an email when a new federal OSHA severe-injury report for Morgan Engineering Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
1182 EAST SUMMIT STREET
City
ALLIANCE
State
OH
ZIP
44601
Mailing
1049 SOUTH MAHONING AVENUE, ALLIANCE, OH 44601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333923
Employees
47
Ownership type
A

4 citations on file for this inspection.

1910.36 D01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 15, 2014
Abate by
Jul 23, 2014
Penalty
Initial $1,890 · Current $1,150 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    On or about March 28, 2014, at the Structure Shop, the exit door next to the welding area was bolted shut during work hours.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $1890

1910.146 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 15, 2014
Abate by
Aug 29, 2014
Penalty
Initial $1,890 · Current $1,150 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:     On or about March 28, 2014, at the Structure Shop, the employer failed to evaluate the crane girders that employees enter to perform welding as permit required confined spaces.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $1890

1910.253 B04 III

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 15, 2014
Abate by
Jul 23, 2014
Penalty
Initial $1,890 · Current $1,150 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    On or about March 28, 2014, outside of the Structure Shop, at least four oxygen cylinders were stored next to eight propane cylinders.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $1890

1910.157 G02

Other-than-serious 1 instance 60 exposed
Issued
Jul 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter.  On or about March 26, 2014, portable fire extinguishers were available for employees to use, but initial and annual training were not provided.   Note the employer may exercise one of the following options:   1. Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as specified in 29 CFR 1910.157(g).  The other sections of 29 CFR also apply.   2. Provide extinguishers as specified in 29 CFR 1910.157(c)(1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sound of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(a) and train/educate designated employees per 1910.157(g).  Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d).   3. Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy shall include an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and 29 CFR 1910.39(a).  Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to the use/storage of flammable/combustible liquids).  If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Morgan Engineering Systems INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339648925.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.