Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DELINE BOX COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DELINE BOX COMPANY in 3700 LIMA STREET, DENVER, CO 80239 (NAICS 322213). OSHA activity number 339652844.

Watch Deline BOX Company — free Get an email when a new federal OSHA severe-injury report for Deline BOX Company is published. One employer, no account, unsubscribe in one click.
Establishment
DELINE BOX COMPANY
Site address
3700 LIMA STREET
City
DENVER
State
CO
ZIP
80239
Mailing
3700 LIMA STREET, DENVER, CO 80239
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322213
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2975.00 · Current $2083.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:          a)    DeLine Box Company at 3700 Lima Street, Denver, CO 80239: On and before 3/10/14, the employer did not protect employees from hazards created by operating an unguarded portion of a Langstan Saturn III 50 inch model flexo folder gluer. This condition exposed employees to an amputation hazard of the roller conveyor.     b)    DeLine Box Company at 3700 Lima Street, Denver, CO 80239: On and before 3/10/14, the employer did not protect employees from hazards created by operating an unguarded portion of a Langstan Saturn III 50 inch model flexo folder gluer. This condition exposed employees to an amputation hazard of the rollers on the folding section.       Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2083
  • — Z (S) $2975

1910.303 G02 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1253.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:    (a)     DeLine Box Company at 3700 Lima Street, Denver, CO 80239: On and before 3/10/14, the electrical connection for the Saturn III equipment had exposing live electrical connections to the foot pedal.  This condition exposed the employees to the hazard of electrical shock and burns.          Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $1253
  • — Z (S) $1785

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339652844.