TONAWANDA, NY —
OSHA Inspection: FREEDOM RESTORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FREEDOM RESTORATION in 2100 SHERIDAN DRIVE, TONAWANDA, NY 14223 (NAICS 238310). OSHA activity number 339655078.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FREEDOM RESTORATION
- Site address
- 2100 SHERIDAN DRIVE
- City
- TONAWANDA
- State
- NY
- ZIP
- 14223
- Mailing
- 461 HINMAN AVENUE, BUFFALO, NY 14216
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.403 I02 I
- Issued
- May 9, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) On or about 3/31/14, on the first floor of the Sheridan Residence Apartment Complex under renovation, 2100 Sheridan Dr., Tonawanda, NY: The cord on a DeWalt Radio did not have a plug. Instead, the hot and neutral conductors were hanging out of the end of the cord, and were inserted into the hot & neutral slots at the female end of an extension cord. Furthermore, a drywall screw was inserted part way into the hot & neutral slots at the female end of the extension cord to keep the conductors from falling out. The drywall screw inserted into and sticking out of the hot slot of the receptacle was energized at 120 volts-ac. b) On or about 3/31/14, on the second floor of the Sheridan Residence Apartment Complex under renovation, 2100 Sheridan Dr., Tonawanda, NY: A light socket in a string of temporary lights did not have a bulb in the socket and was not guarded. The socket was exposed & energized at 120 volts-ac. c) On or about 3/31/14, on the second floor of the Sheridan Residence Apartment Complex under renovation, 2100 Sheridan Dr., Tonawanda, NY: A light socket in a string of temporary lights did not have a bulb in the socket. The socket did have a bulb guard, but the openings in the guard were very large. The socket was exposed & energized at 120 volts-ac. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $2000
1926.405 A02 II E
- Issued
- May 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) On or about 3/31/14, on the second floor of the Sheridan Residence Apartment Complex under renovation, 2100 Sheridan Dr., Tonawanda, NY: One light socket in a string of temporary lights contained a florescent light bulb, but did not have a bulb guard. Another contained an incandesent light bulb, but only had one half of a bulb guard. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $0
1926.404 F06
- Issued
- May 9, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 3/31/14, on the first floor of the Sheridan Residence Apartment Complex under renovation, 2100 Sheridan Dr., Tonawanda, NY: A series of three extension cords supplied 120 volt- ac power to a DeWalt, Model DW367, 7 1/4" circular saw and a DeWalt radio. The plugs on the first and last extension cords in the series lacked a grounding prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $1020
1926.416 E01
- Issued
- May 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 3/31/14, on the first floor of the Sheridan Residence Apartment Complex under renovation, 2100 Sheridan Dr., Tonawanda, NY: A series of three extension cords supplied 120 volt- ac power to a DeWalt, Model DW367, 7 1/4" circular saw and a DeWalt radio. The outer sheath of the first extension cord in the series was frayed at the female end, exposing the conductors. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $0
More inspections at Freedom Restoration
View Freedom Restoration's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339655078.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.