Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUTUMN VIEW GARDENS

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AUTUMN VIEW GARDENS in 11210 SCHUETZ RD., SAINT LOUIS, MO 63146 (NAICS 623311). OSHA activity number 339656407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Autumn View Gardens — free Get an email when a new federal OSHA severe-injury report for Autumn View Gardens is published. One employer, no account, unsubscribe in one click.
Establishment
AUTUMN VIEW GARDENS
Site address
11210 SCHUETZ RD.
City
SAINT LOUIS
State
MO
ZIP
63146
Mailing
11210 SCHUETZ RD., SAINT LOUIS, MO 63146
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
623311
Employees
45
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative  a/ At the facility for maintenance employee(s) who performed servicing or maintenance on equipment including but not limited to GFI outlets, a written lockout tag out program had not been developed.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.147 D03

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3)  All energy isolating devices that are needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  For the maintenance employee who repaired GFI outlets without locking out the circuit breaker or equivalent.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 8, 2014
Abate by
Jul 8, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts:  In the kitchen, for cooks who used the HOBART A-200 mixer (SN #11-125-141) to mix brownies and cake mix without a guard for the rotating parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that will prevent pull from being directly transmitted to joints or terminal screws:    In the kitchen the cord and plug belonging to the HOBART A-200 (SN # 11-125-141) mixer lacked strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  In the kitchen, for employees who used GREASESTRIP PLUS to clean ovens and LIME-A-WAY, an approved eyewash with a continual upright stream of water was not available for immediate emergency use.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.1030 F01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 8, 2014
Abate by
May 23, 2014
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.1030(f)(1)(ii) (D): The employer shall ensure that all medical evaluations and procedures including the hepatitis B vaccine and vaccination series and post-exposure evaluation and follow-up, including prophylaxis, are provided according to recommendations of the U.S. Public Health Service current at the time these evaluations and procedures take place, except as specified by this paragraph (f):  At the facility, for employee(s) with ongoing daily use of sharps including but not limited to certified medical technicians, antibody testing was not provided within 1-2 months after completion of the Hepatitis B vaccination series of three shots:
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

View Autumn View Gardens's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339656407.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.