MASON, OH —
OSHA Inspection: FIELD CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FIELD CONSTRUCTION, LLC in 5265 NATORP DR., MASON, OH 45040 (NAICS 238130). OSHA activity number 339659526.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FIELD CONSTRUCTION, LLC
- Site address
- 5265 NATORP DR.
- City
- MASON
- State
- OH
- ZIP
- 45040
- Mailing
- 3015 KANT PL., BEAVERCREEK, OH 45431
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 B01 II
- Issued
- May 30, 2014
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. Located at the middle condominium unit workers utilized a Porter Cable circular saw that was connected with a 50.0 foot yellow extension cord to the electrical service to cut wooden framing material. Workers were exposed to potential electrocution hazards in that the electrical service was not protected with a ground-fault circuit interrupter nor was an assured equipment grounding conductor program in use.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1926.453 B02 V
- Issued
- May 30, 2014
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note: As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. Workers were engaged in commercial construction activities installing wooden framing material on new multi-story condominiums. Workers utilized a JLG 600S articulating, extensible, boom aerial lift and were exposed to 40.0 foot fall hazards in that the workers were not attached to the basket or mast.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
More inspections at Field Construction, LLC
View Field Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339659526.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.