DEXTER, MO ·
OSHA Inspection: BOOTHEEL RECYCLING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOOTHEEL RECYCLING INC. in 202 N. HARRIS DRIVE, DEXTER, MO 63841 (NAICS 423930). OSHA activity number 339661365.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOOTHEEL RECYCLING INC.
- Site address
- 202 N. HARRIS DRIVE
- City
- DEXTER
- State
- MO
- ZIP
- 63841
- Mailing
- 202 N. HARRIS DRIVE, DEXTER, MO 63841
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 9
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Apr 8, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: Periodic audits of the specific lockout/tagout procedures for the following machines were not performed: a/ Propane Forklift. b/ Diesel Forklift. c/ Bobcat. d/ Diesel Tractor. e/ MAXPACK Baler.
Recent events (1)
- · Z (O) $0
1910.303 F01
- Issued
- Apr 8, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by this subpart for motors and appliances was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident: a/ Throughout the processing facility, all of the disconnecting means were not legibly marked to indicate the voltage.
Recent events (1)
- · Z (O) $0
1910.303 F02
- Issued
- Apr 8, 2014
- Abate by
- May 23, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose was evident: a/ Inside of the processing facility, the circuit breaker panel boxes were not legibly marked with the amount of voltage.
Recent events (1)
- · Z (O) $0
More inspections at Bootheel Recycling INC.
View Bootheel Recycling INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339661365.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.