CARLISLE, PA —
OSHA Inspection: KEEN TRANSPORT, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEEN TRANSPORT, INC. in 1951 HARRISBURG PIKE, CARLISLE, PA 17013 (NAICS 484230). OSHA activity number 339664237.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEEN TRANSPORT, INC.
- Site address
- 1951 HARRISBURG PIKE
- City
- CARLISLE
- State
- PA
- ZIP
- 17013
- Mailing
- 1951 HARRISBURG PIKE, CARLISLE, PA 17013
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484230
- Employees
- 420
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 D04 I
- Issued
- Jun 18, 2014
- Abate by
- Aug 5, 2014
- Penalty
- Initial $4,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): Inside storage rooms for flammable and combustible liquids had openings to other rooms or buildings that were not provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height; or the floor in the storage area was not at least 4 inches below the surrounding floor; or the inside of the room did not have an open-grated trench which drained to a safe location. Openings from inside flammable and combustible liquid storage rooms were not provided with approved self-closing fire doors: (a) Assembly Services, Flammable and Combustible Liquid Storage Rooms behind the Paint Booths - The employer had two inside storage rooms for storing flammable and combustible liquids, including, but not limited to, PPG Shop-Line Slow Reducer JR507, PPG Shop-Line General Purpose Solvent JT501, and PPG Shop-Line Wax and Grease Remover JX101 (all Category 2 flammable liquids). These inside storage rooms did not have either noncombustible liquid-tight raised sills or ramps at least 4 inches in height; or floors in the storage rooms at least 4 inches below the surrounding floor; or the inside of the room did not have an open-grated trench which drained to a safe location. In addition, the opening to each of these inside storage rooms had double doors, but only the right side door of each set of doors was self-closing, exposing employees to a fire hazard, on or about April 8, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.106 E06 II
- Issued
- Jun 18, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $4,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees F (37.8 degrees C), were dispensed into containers without the nozzle and container being electrically interconnected: (a) Assembly Services, Flammable and Combustible Liquid Storage Rooms behind the Paint Booths - Employees dispensed PPG Shop-Line Slow Reducer JR507 (a Category 2 flammable liquid) from a 55-gallon drum to a 5-gallon container. The container had a plastic opening which prevented the bonding of this container to the nozzle on the 55-gallon drum, and employees did not use a bond wire to electrically bond the 55-gallon drum to the 5-gallon container, exposing employees to a fire hazard, on or about April 8, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.106 E09 III
- Issued
- Jun 18, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $4,000 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) Assembly Services, Paint Booths - Inside the paint booths, the employer had ordinary plastic garbage cans filled with combustible waste, including, but not limited to, a used up can of PPG Shop-Line General Purpose Solvent JT501 (a Category 2 flammable liquid), used sanding discs, and used Tyvek coveralls. In addition, the employer kept a metal 55-gallon drum in each paint booth for employees to use to dispose of waste PPG Shop-Line General Purpose Solvent JT501 (a Category 2 flammable liquid). Neither the garbage cans nor the waste solvent drums got emptied on a daily basis, exposing employees to a fire hazard, on or about April 8, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3000
- — Z (S) $4000
1910.147 C06 I
- Issued
- Jun 18, 2014
- Abate by
- Jul 23, 2014
- Penalty
- Initial $5,000 · Current $3,750 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Keen Transport, Inc., 1951 Harrisburg Pike, Carlisle, Pennsylvania - Employees did servicing and maintenance work on machinery and equipment, including, but not limited to, repairing and maintaining trucks and trailers and setting up equipment by adding pre-lube kits, hydraulic kits, etc., and the employer did not conduct an annual inspection of the energy control procedures to identify and correct any inadequacies or deviations, exposing employees to caught-in, struck-by and other hazards resulting from unexpected energization, on or about April 8, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3750
- — Z (S) $5000
1910.134 F02
- Issued
- Jun 18, 2014
- Abate by
- Aug 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employees using tight-fitting facepiece respirators were not annually fit tested: (a) Keen Transport, Inc., 1951 Harrisburg Pike, Carlisle, Pennsylvania - Employees used half-mask tight-fitting negative pressure respirators while performing work activities, such as spray painting. The employer did not ensure that each employee received an annual fit test, exposing employees to injurious contact with hazardous chemicals, including, but not limited to, organic compounds contained in the paints, on or about April 8, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 G01 I A
- Issued
- Jun 18, 2014
- Abate by
- Aug 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) Keen Transport, Inc., 1951 Harrisburg Pike, Carlisle, Pennsylvania - Employees used half-mask tight-fitting negative pressure respirators while performing work activities, such as spray painting. Some of these employees had facial hair that came between the sealing surface of the facepiece and the face, exposing these employees to injurious contact with hazardous chemicals, including, but not limited to, organic compounds contained in the paints, on or about April 8, 2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Keen Transport, INC.
View Keen Transport, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 484230)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339664237.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.