NEW ORLEANS, LA —
OSHA Inspection: CONSTRUCTION MASTERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONSTRUCTION MASTERS, INC. in 950 S. RENDON ST., NEW ORLEANS, LA 70125 (NAICS 236220). OSHA activity number 339666703.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONSTRUCTION MASTERS, INC.
- Site address
- 950 S. RENDON ST.
- City
- NEW ORLEANS
- State
- LA
- ZIP
- 70125
- Mailing
- P.O. BOX 7968, METAIRIE, LA 70010
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.150 C01 I
- Issued
- May 30, 2014
- Abate by
- Jun 14, 2014
- Penalty
- Initial $3,080 · Current $1,850 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: On or about April 8, 2014; on the second floor of the building, the employer allowed employees to perform work without ensuring that a fire extinguisher was provided for each 3,000 square feet of the protected building area.
Recent events (2)
- — I (S) $1850
- — Z (S) $3080
1926.150 C01 VIII
- Issued
- May 30, 2014
- Abate by
- Jun 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: On or about April 8, 2014; on the second floor of the building, the employer allowed employees to perform work without ensuring that fire extinguishers were inspected periodically and maintained in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- May 30, 2014
- Abate by
- Jun 14, 2014
- Penalty
- Initial $3,080 · Current $1,850 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about April 8, 2014; throughout the jobsite, the employer allowed employees to utilize metallic outlet boxes in a manner that was not in accordance with instructions included in the listing and labeling. a) On the North side of the jobsite, exposed metallic outlet boxes contained light switches that were used to turn the lights on and off. b) At the center of the jobsite, employees plugged an electrical extension cord into an exposed metallic outlet box in order to energize a scissor lift. c) On the South side of the jobsite, exposed metallic outlet boxes contained light switches that were used to turn the lights on and off.
Recent events (2)
- — I (S) $1850
- — Z (S) $3080
1926.405 B01
- Issued
- May 30, 2014
- Abate by
- Jun 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: On or about April 8, 2014; at the center of the jobsite, the employer allowed employees to plug an electrical extension cord into a metallic outlet box that was not effectively closed in order to energize a scissor lift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B02
- Issued
- May 30, 2014
- Penalty
- Initial $3,080 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: On or about April 8, 2014; on the first floor of the building, the employer allowed employees to use and work near two (2) outlet boxes (energized light switches) that were not covered. a) On the North side of building, light switch missing faceplate. b) On the South side of building, light switch missing faceplate.
Recent events (2)
- — I (S) $0
- — Z (S) $3080
More inspections at Construction Masters, INC.
View Construction Masters, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339666703.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.