ATLANTA, GA —
OSHA Inspection: UTILITY LINES CONSTRUCTION SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UTILITY LINES CONSTRUCTION SERVICES, INC. in 2640 WINDY HILL ROAD, ATLANTA, GA 30339 (NAICS 221122). OSHA activity number 339667248.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UTILITY LINES CONSTRUCTION SERVICES, INC.
- Site address
- 2640 WINDY HILL ROAD
- City
- ATLANTA
- State
- GA
- ZIP
- 30339
- Mailing
- 276 FIRST STREET, FOREST PARK, GA 30297
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221122
- Employees
- 100
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- May 8, 2014
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Trench, located at 2640 Windy Hill Road, Atlanta, GA 30339: Employee working in a trench which measured approximately 7-feet deep x 3-feet wide x 13-feet long was not provided with a safe means of egress, i.e. ladder and or ramp.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1926.652 A01
- Issued
- May 8, 2014
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). the employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the excavation was sloped at an angle steeper than one-half horizontal to one vertical. a) Trench located at 2640 Windy Hill Road, Atlanta, GA 30339: Employee was exposed to soil cave-ins while shoveling around utility wires and electrical cables in a 7-foot deep x 3-foot wide x 13-foot long excavation with no cave-in protection system in place.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
More inspections at Utility Lines Construction Services, INC.
View Utility Lines Construction Services, INC.'s full OSHA safety record →