OSHA Inspection: UTILITY LINES CONSTRUCTION SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of UTILITY LINES CONSTRUCTION SERVICES, INC. in 2640 WINDY HILL ROAD, ATLANTA, GA 30339 (NAICS 221122). OSHA activity number 339667248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utility Lines Construction Services, INC. — free Get an email when a new federal OSHA severe-injury report for Utility Lines Construction Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2640 WINDY HILL ROAD
City
ATLANTA
State
GA
ZIP
30339
Mailing
276 FIRST STREET, FOREST PARK, GA 30297
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
100
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 8, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) Trench, located at 2640 Windy Hill Road, Atlanta, GA 30339: Employee working in a trench which measured approximately 7-feet deep x 3-feet wide x 13-feet long was not provided with a safe means of egress, i.e. ladder and or ramp.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.652 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 8, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). the employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the excavation was sloped at an angle steeper than one-half horizontal to one vertical.  a) Trench located at 2640 Windy Hill Road, Atlanta, GA 30339: Employee was exposed to soil cave-ins while shoveling around utility wires and electrical cables in a 7-foot deep x 3-foot wide x 13-foot long excavation with no cave-in protection system in place.