Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AFFORDABLE EXTERIORS LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AFFORDABLE EXTERIORS LLC in STONEY RIVER MEMORY CARE, MARSHFIELD, WI 54472 (NAICS 238160). OSHA activity number 339674921.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Affordable Exteriors LLC — free Get an email when a new federal OSHA severe-injury report for Affordable Exteriors LLC is published. One employer, no account, unsubscribe in one click.
Site address
STONEY RIVER MEMORY CARE
City
MARSHFIELD
State
WI
ZIP
54472
Mailing
19572 CTY F, BLOOMER, WI 54724
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 19, 2014
Abate by
Jul 3, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   On 4/2/14, employees performing roofing work with pneumatic nail guns were not wearing safety glasses.
Recent events (3)
  • — F (S) $1600
  • — C (S) $1600
  • — Z (S) $1600

1926.502 D06 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 19, 2014
Abate by
Jul 3, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.502(d)(6)(iii): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself:  On 4/2/14, two lifelines were connected to the same roof anchor on the window sill of the cupola.
Recent events (3)
  • — F (S) $2000
  • — C (S) $2000
  • — Z (S) $2000

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 19, 2014
Abate by
Jul 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee:  On 4/2/14, two lifelines for personal fall arrest systems were connected to the same anchor that was nailed to the window sill of the cupola which would not be able to support 10,000# of force in the event of a double fall.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 19, 2014
Abate by
Jul 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:  On 4/2/14, an employee applying shingles to the roof was working diagonally away from his anchor point, farther horizontally than vertically, which would allow him to fall farther than 6' before his fall arrest system would function.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B11

Willful Gravity 10 1 instance 8 exposed
Issued
Jun 19, 2014
Abate by
Jul 3, 2014
Penalty
Initial $14,000 · Current $14,000
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  On 4/2/14, employees were roofing a building without complete personal fall arrest systems in place.
Recent events (3)
  • — F (W) $14000
  • — C (W) $14000
  • — Z (W) $14000

View Affordable Exteriors LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339674921.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.