Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: ALAN WIRE COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALAN WIRE COMPANY in 830 SOUTH WEST STREET, SIKESTON, MO 63801 (NAICS 331222). OSHA activity number 339675076.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alan Wire Company for free Get an email when a new federal OSHA severe-injury report for Alan Wire Company is published. One employer, no account, unsubscribe in one click.
Establishment
ALAN WIRE COMPANY
Site address
830 SOUTH WEST STREET
City
SIKESTON
State
MO
ZIP
63801
Mailing
830 SOUTH WEST STREET, SIKESTON, MO 63801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331222
Employees
126
Ownership type
Private (A)

5 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 22, 2014
Abate by
Nov 7, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   Plant: Machine specific lockout/tag out procedures were not developed and instituted for employees who performed repairs and servicing of machines such as, but not limited to, an insulated copper baler.
Recent events (2)
  • · I (S) $2677.5
  • · Z (S) $3825

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 22, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    Baling Area: Insulated copper wire baler was not guarded to prevent employee exposure to point of operation hazards.
Recent events (2)
  • · I (S) $2677.5
  • · Z (S) $3825

1910.305 B01 II

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 22, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Panel Box 14: Employees were exposed to electrical hazards where unused circuit breaker holes in an electrical panel box were not covered.
Recent events (2)
  • · I (S) $2677.5
  • · Z (S) $3825

1910.305 G01 IV A

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 22, 2014
Abate by
Oct 9, 2014
Penalty
Initial $3,825 · Current $2,678 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   Blow Down Solenoid area: A flexible cord set was used as a substitute for fixed wiring, exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $2677.5
  • · Z (S) $3825

1910.305 G02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 22, 2014
Abate by
Oct 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    Blow down Solenoid Valve: A flexible cord set (extension cord) was spliced into a power cord of a motor, exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Alan Wire Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339675076.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.