ELMA, NY —
OSHA Inspection: BUILDING SOLUTIONS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUILDING SOLUTIONS INC. in 6300 SENECA STREET, ELMA, NY 14059 (NAICS 238160). OSHA activity number 339687469.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUILDING SOLUTIONS INC.
- Site address
- 6300 SENECA STREET
- City
- ELMA
- State
- NY
- ZIP
- 14059
- Mailing
- 6091 SENECA STREET, ELMA, NY 14059
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.403 I02 I
- Issued
- May 5, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; the distribution panel on the first floor operating at 240/120 volts did not have a cover. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.404 F06
- Issued
- May 5, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; extension cords used to power portable tools were missing ground prongs. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.451 B02 II
- Issued
- May 5, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(2)(ii): When walkways between scaffold sections are less than 18 inches wide, employees were not protected from falls by guardrail systems or personal fall arrest systems: a) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; an employee using a step ladder scaffold with a platform width of 12 inches was not protected from falling approximately 12 feet of from the end of the scaffold. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.501 B10
- Issued
- May 5, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Employee(s) engaged in roofing activities on low-sope roofs, with unprotected sides and edges 6 feet (1.8m) or more above lower levels were not protected from falling by a guardrail system, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; employee installing metal roofing on a hip roof with a 4 in 12 pitch and an eave height of approximately 16 feet were not protected from falling. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- May 5, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; employees were using a 10 foot step ladder to access the cupola roof. The side rails were only 2 feet above the eave. b) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; employees were using an extension ladder to access the main roof. The side rails were only 18 inches above the landing. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.1053 B16
- Issued
- May 5, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) On or about 4/17/14 at a roof replacement project located at 6300 Seneca Street, Elma, New York; employees were using a broken 10 foot step ladder to access the roof of the cupola. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $600
- — Z (S) $1200
More inspections at Building Solutions INC.
View Building Solutions INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339687469.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.