KLAMATH FALLS, OR —
OSHA Inspection: OREGON AIR NATIONAL GUARD, 173RD FW
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OREGON AIR NATIONAL GUARD, 173RD FW in 211 ARNOLD AVENUE, SUITE 12, KLAMATH FALLS, OR 97603 (NAICS 488190). OSHA activity number 339698706.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OREGON AIR NATIONAL GUARD, 173RD FW
- Site address
- 211 ARNOLD AVENUE, SUITE 12
- City
- KLAMATH FALLS
- State
- OR
- ZIP
- 97603
- Mailing
- 211 ARNOLD AVENUE, SUITE 12, KLAMATH FALLS, OR 97603
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488190
- Employees
- 240
- Ownership type
- D
Citations
3 citations on file for this inspection.
1910.132 E
- Issued
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(e): The employer did not ensure that employees were not using defective or damaged personal protective equipment in the workplace. (a) Wash bay: On or about April 15, 2014 and times prior thereto, the gate on the fall protection snap hook did not close. This exposed employees to a potential fall of ten feet off the aircraft surface.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- May 1, 2014
- Abate by
- Jun 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Phase hanger bay 1: On or about April 15, 2014 and times prior thereto, there was an unused opening on the electrical panel. This exposed employees to potential shock hazards if they came in contact with the bus bar.
Recent events (1)
- — Z (S) $0
1910.37 A04
- Issued
- May 1, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: Phase hanger: On or about April 15, 2014 and times prior thereto, the emergency light was not operational. This exposed employees to tripping/smoke inhalation hazards from delays in exiting the building.
Recent events (1)
- — Z (O) $0
More inspections at Oregon AIR National Guard, 173RD FW
View Oregon AIR National Guard, 173RD FW's full OSHA safety record →
More inspections in this industry (NAICS 488190)
More inspections in OR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339698706.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.