Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ECOLIT, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ECOLIT, INC. in 1945 W. FULTON, CHICAGO, IL 60626 (NAICS 541410). OSHA activity number 339702904.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ecolit, INC. — free Get an email when a new federal OSHA severe-injury report for Ecolit, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ECOLIT, INC.
Site address
1945 W. FULTON
City
CHICAGO
State
IL
ZIP
60626
Mailing
1945 W. FULTON, CHICAGO, IL 60612
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541410
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.134 C02 II

Other-than-serious 1 instance 3 exposed
Issued
May 30, 2014
Abate by
Jul 17, 2014
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.134(c)(2)(ii): The employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks):    On or about April 21, 2014, in the facility, employees required to perform LED sign manufacturing were provided with half-mask, air-purifying respirators in the workplace.  The employer did not establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use did not present a health hazard to the user.
Recent events (2)
  • — I (O) $600
  • — Z (S) $1200

1910.1025 L01 I

Other-than-serious 1 instance 3 exposed
Issued
May 30, 2014
Abate by
Jul 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1025(l)(1)(i): Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation:  On or about April 21, 2014, in the facility, employees required to perform LED sign manufacturing were potentially exposed to airborne lead when soldering with lead-based solder.  The employer did not inform employees of the content of Appendices A and B of the regulation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
May 30, 2014
Abate by
Jul 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:  On or about April 21, 2014, in the facility, employees required to perform LED sign manufacturing were exposed to the hazard of contact with metal, cellulose and/or acrylic dust from saw cutting operations, and lead fume or dust from hand soldering operations with lead-based solder. The employer did not develop, implement, and maintain at the workplace a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of the standard will be met.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Ecolit, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339702904.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.