Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLUMBUS CASTINGS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLUMBUS CASTINGS in 2211 PARSONS AVENUE, COLUMBUS, OH 43207 (NAICS 331513). OSHA activity number 339738601.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Columbus Castings — free Get an email when a new federal OSHA severe-injury report for Columbus Castings is published. One employer, no account, unsubscribe in one click.
Establishment
COLUMBUS CASTINGS
Site address
2211 PARSONS AVENUE
City
COLUMBUS
State
OH
ZIP
43207
Mailing
2211 PARSONS AVENUE, COLUMBUS, OH 43207
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331513
Employees
700
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 30, 2014
Abate by
Oct 17, 2014
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    a. In department 2, core room, the employer did not ensure that lock out procedures gave specific procedural steps for blocking and bleeding the hydraulic pressure on the EMI blower machine.
Recent events (3)
  • — F (S) $4900
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C04 II C

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 30, 2014
Abate by
Oct 17, 2014
Penalty
Initial $5,500 · Current $3,850 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:    29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.    a. In department 2, core room, the employer did not include specific procedures for the removal of lockout devices or tagout devices when restarting/re-energizing the EMI machine.
Recent events (3)
  • — F (S) $3850
  • — C (S) $5500
  • — Z (S) $5500

1910.147 C07 IV

Repeat Gravity 10 1 instance 4 exposed
Issued
Sep 30, 2014
Abate by
Nov 2, 2014
Penalty
Initial $38,500 · Current $38,500
29 CFR 1910.147(c)(7)(iv): The employer shall certify that employee training has been accomplished and is being kept up to date. The certification shall contain each employee's name and dates of training:    a.  The Respondent did not maintain records certifying that authorized employees in the Core Room, Department 2, received required training for energy isolation and control, before operating the EMI blower, which required lockout/tag out procedures to be followed during daily operations.
Recent events (3)
  • — F (R) $38500
  • — C (R) $38500
  • — Z (R) $38500

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 30, 2014
Abate by
Oct 10, 2014
Penalty
Initial $38,500 · Current $7,000 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    a. In the core room, department 2, the employer did not ensure guards were in place at the point of operation on the EMI blower.    The Columbus Steel Castings Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.212(a)(3)(ii), which was contained in OSHA inspection number 313148207, citation number 2, item number 2 and was affirmed as a final order on November 25, 2010, with respect to a workplace located at 2211 Parsons Ave, Columbus, OH 43207.
Recent events (3)
  • — F (S) $7000
  • — C (R) $38500
  • — Z (R) $38500

View Columbus Castings's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339738601.