Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEN-RUBBER LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GEN-RUBBER LLC in 352 SOUTH STREET, GALION, OH 44833 (NAICS 326299). OSHA activity number 339740284.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gen-Rubber LLC — free Get an email when a new federal OSHA severe-injury report for Gen-Rubber LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GEN-RUBBER LLC
Site address
352 SOUTH STREET
City
GALION
State
OH
ZIP
44833
Mailing
352 SOUTH STREET, GALION, OH 44833
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
24
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 1, 2014
Abate by
Oct 20, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Gen-Rubber LLC, Galion, Ohio:  On or about September 17, 2014, the employer did not ensure that the auger on the Granulator #1 screw conveyor was guarded to protect employees from crushing and amputation hazards.        b) Gen-Rubber LLC, Galion, Ohio:  On or about September 16, 2014, the employer did not ensure that the auger on the Veco screw conveyor, located near Granulator #1, was guarded to protect employees from crushing and amputation hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 1, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):     a) Gen-Rubber LLC, Galion, Ohio:  On or about April 16, 2014, the employer did not ensure that the rotating drive pulley and belt, mounted on the hopper which feed the granulator #1 screw conveyor, was properly guarded.  Employees were exposed to amputation hazards if they were to inadvertently contact the belt and pulley nip point.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 B02

Serious Gravity 5 1 instance 24 exposed
Issued
Oct 1, 2014
Abate by
Oct 20, 2014
Penalty
Initial $2,400 · Current $1,200 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:     a) Gen-Rubber LLC, Galion, Ohio:  On or about September 17, 2014, the employer did not ensure that electrical equipment utilized by employees was being used as listed, in that a relocatable power tap (110 volts) was being used in the granulator area to power a water pump.  The relocatable power tap was brown and melted where the pump was plugged in, exposing employees to burn hazards in the event of a fire.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.305 B01 II

Serious Gravity 5 1 instance 24 exposed
Issued
Oct 1, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     a) Gen-Rubber LLC, Galion, Ohio:  On or about April 16, 2014, the employer did not ensure that the unused opening in the 220 volt AC panelboard cabinet, located near granulator #1 was effectively closed to prevent damage to energized circuits. Inside of the panelboard, there was a circuit breaker missing, creating an opening to energized circuit, exposing employees to shock and fire hazards.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

View Gen-Rubber LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339740284.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.