LINCOLN, NE —
OSHA Inspection: VEYANCE TECHNOLOGIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VEYANCE TECHNOLOGIES, INC. in 4021 N 56TH STREET, LINCOLN, NE 68504 (NAICS 326299). OSHA activity number 339743346.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VEYANCE TECHNOLOGIES, INC.
- Site address
- 4021 N 56TH STREET
- City
- LINCOLN
- State
- NE
- ZIP
- 68504
- Mailing
- 4021 N 56TH STREET, LINCOLN, NE 68504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 450
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Aug 1, 2014
- Abate by
- Apr 15, 2015
- Penalty
- Initial $3,400 · Current $4,000
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: The employer is failing to protect employees from fall hazards in the mezzanine in the Banbury Area. This area is not properly guarded by a standard guard rail system consisting of top rails and mid rails installed at the required heights from the working surface
Recent events (3)
- — F (S) $4000
- — C (S) $3400
- — Z (S) $3400
1910.176 B
- Issued
- Aug 1, 2014
- Abate by
- Apr 15, 2015
- Penalty
- Initial $3,400 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: The employer is failing to ensure that the storage racks in this facility are secure. Storage racks, storing various parts and materials including, but not limited to spare machine parts, fans, and maintenance type items were not secured to prevent the system from moving if struck by forklifts over time. Employees are exposed to struck-by hazards.
Recent events (3)
- — F (O) $1500
- — C (S) $3400
- — Z (S) $3400
1910.213 H04
- Issued
- Aug 1, 2014
- Abate by
- Apr 15, 2015
- Penalty
- Initial $4,250 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: The employer is failing to protect employees from laceration hazards by not ensuring the equipment is properly set up so the cutting head of the radial arm saw always returns to the starting position. When extended, the cutting head would not return to the starting position.
Recent events (3)
- — F (S) $4000
- — C (S) $4250
- — Z (S) $4250
1910.303 B02
- Issued
- Aug 1, 2014
- Abate by
- Apr 15, 2015
- Penalty
- Initial $3,400 · Current $4,000
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: The employer is failing to ensure employees are protected from electrical hazards. Employees are working with an electrical outlets box in the immediate vicinity of the reverse osmosis equipment located east of the Positive Drive cell which is not being used in accordance with its listing and labeling. The outlet box is attached to the end of a flexible cord to form an extension cord which has 2 plugs. The type of box being used is designed for use in an enclosed wall. It is not designed to withstand the damage and use as a portable box.
Recent events (3)
- — F (S) $4000
- — C (S) $3400
- — Z (S) $3400
1910.303 G01 II
- Issued
- Aug 1, 2014
- Abate by
- Apr 15, 2015
- Penalty
- Initial $4,250 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: The employer is failing to ensure that the areas in front of circuit breaker panel boxes are free from obstruction and able to be readily accessed. The panel box located in the "Dallas Palace" was blocked by numerous pieces of furniture, equipment and materials. This impedes access to the box in an emergency situation in which the electricity would need to be turned off at the box.
Recent events (3)
- — F (O) $1500
- — C (S) $4250
- — Z (S) $4250
More inspections at Veyance Technologies, INC.
View Veyance Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326299)
More inspections in NE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339743346.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.