On , OSHA opened a federal Agency safety inspection of NBC OILFIELD EQUIPMENT INC. in CR 230, WEIMAR, TX 78962 (NAICS 213112). OSHA activity number 339743601.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NBC OILFIELD EQUIPMENT INC.
- Site address
- CR 230
- City
- WEIMAR
- State
- TX
- ZIP
- 78962
- Mailing
- 6115 HIGHWAY 36 WEST, WALLIS, TX 77485
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.145 C03
- Issued
- Oct 16, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): On or about April 22, 2014 and times prior thereto, located at the Ray Corcoran Gas Unit Well#1: (a) No signage was present for piping, vessels and tanks that are protected from very high pressure gas by a valve at a remote location. Signs are needed to inform workers at the site of the active well that is remotely located from the from the tanks and vessels. (b) Pipes and valves were not identified as to their purpose. The flare line and valve were not identified. This condition created a hazard of closing the flare line when it needed to be open to relieve excess pressure. Improper valve operation could cause catastrophic failure of the separator tank resulting in serious physical injury or death.
Recent events (2)
- — I (O) $3500
- — Z (S) $7000
1910.147 C01
- Issued
- Oct 16, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about April 22, 2014 located at the Ray Corcoran Gas Unit Well#1 workers installed a ball valve in a line extending from a separator tank without first ensuring that the high pressure wellhead was locked in the closed position. This condition exposed the workers to the hazards of fire and being struck by shrapnel in the event of a pressure release or catastrophic overpressure of the separator.
Recent events (2)
- — I (S) $5000
- — Z (S) $7000
1910.1200 H03 III
- Issued
- Oct 16, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: On or about April 22, 2014 and in times prior thereto the employer at the Ray Corcoran Gas unit Well #1 well site did not provide effective training in the emergency procedures to evacuate immediately when leaking flammable chemical under pressure was detected, exposing employees to the hazards of fire and chemical splashes.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
More inspections at NBC Oilfield Equipment INC.
View NBC Oilfield Equipment INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339743601.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.