Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN WALNUT LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AMERICAN WALNUT LLC in 2801 SOUTH 2ND STREET, SAINT JOSEPH, MO 64501 (NAICS 321113). OSHA activity number 339746588.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Walnut LLC — free Get an email when a new federal OSHA severe-injury report for American Walnut LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN WALNUT LLC
Site address
2801 SOUTH 2ND STREET
City
SAINT JOSEPH
State
MO
ZIP
64501
Mailing
2801 SOUTH 2ND STREET, SAINT JOSEPH, MO 64501
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
45
Ownership type
A

18 citations on file for this inspection.

1910.23 A08

Serious Gravity 5 2 instances 6 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $1,050 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:    (a) At American Walnut LLC on or about April 28, 2014 workers were exposed to stepping into floor holes.  Floor holes were left unprotected along the walkway that the slab handler for the round blade head saw used.      (b) At American Walnut LLC on or about April 28, 2014 workers were exposed to stepping into floor holes.  Floor holes were left unprotected on the deck used by the log handler ahead of both head saws.      NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $4200

1910.23 B01

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.23(b)(1): Every wall opening from which there was a drop of more than 4 feet was not guarded.  (a) At American Walnut LLC on or about April 28, 2014 workers were exposed to a wall opening along the log deck that was not guarded.  The height of the opening measure 52 7/8 inches.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1910.23 D01

Serious Gravity 5 3 instances 45 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $4,200
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails:  (a) At American Walnut on or about April 28, 2014 had a set of steps with five risers that did not have standard stair railings on either side of the open sided steps.  The railing that was present on one side did not have a midrail.  There was no railing on the other open side.  (b) At American Walnut on or about April 28, 2014 had a set of steps less than 44 inches wide and 7 risers high.  The steps had no railing on either open side.  (c) At American Walnut on or about April 28, 2014 had a set of steps with five risers that did not have standard railings on either open side.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $4200

1910.24 H

Serious Gravity 5 4 instances 45 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:  (a) At American Walnut on or about April 28, 2014 had a set of steps with five risers that did not have standard stair railings on either side of the open sided steps.  The railing that was present on one side did not have a midrail.  There was no railing on the other open side.  (b) At American Walnut on or about April 28, 2014 had a set of steps less than 44 inches wide and 7 risers high.  The steps had no railing on either open side.  (c) At American Walnut on or about April 28, 2014 had a set of steps with five risers that did not have standard railings on either open side.  (d) At American Walnut on or about April 28, 2014 had a set of steps with six risers that did not have standard railings on either side of the open sided steps.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D02

Serious Gravity 5 1 instance 45 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.23(d)(2): Winding stairs were not equipped with a handrail offset to prevent walking on all portions of the treads having width less than 6 inches:    (a) At American Walnut on or about April 28, 2014 winding stairs leading to the walk on one of the the kilns did not have a handrail with offset to prevent walking on all portions of the treads having a width less than 6 inches.      NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.23 E03 V C

Serious Gravity 5 1 instance 45 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(3)(v)(c): Protection between top rail and floor, platform, runway, ramp, or stair treads, equivalent at least to that afforded by a standard intermediate rail was not provided:    (a) At American Walnut on or about April 28, 2014 had a spiral staircase that had vertical newel posts spaced such that they did not afford the same protection as a standard intermediate rail provided.      NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.24 D

Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.24(d): Fixed stairways did not have a minimum width of 22 inches:    (a) At American Walnut LLC on or about April 28, 2014 the steps leading to a basement area near the circular head saw were less than 22 inches wide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1910.24 F

Serious Gravity 5 6 instances 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.24(f): All treads shall be reasonably slip-resistant and the nosings shall be of nonslip finish.  Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:    (a) At American Walnut LLC on or about April 28, 2104 the rise height of steps leading to a walkway over a moving conveyor were not of uniform height.    (b) At American Walnut LLC on or about April 28, 2014 the rise heights of steps leading from the main floor to a basement area near the circular head saw were not of uniform height.    (c) At American Walnut LLC on or about April 28, 2014 the tread depth of steps leading to the work platform for the slab handler at the band head saw were not uniform throughout the flight of stairs.    (d) At American Walnut LLC on or about April 28, 2014 the treads on steps leading to a walkway over a moving conveyor were not reasonably slip-resistant.      (e) At American Walnut LLC on or about April 28, 2014 the treads on steps between different working levels near the circular head saw were not reasonably slip-resistant.  The steps did not have any nosing to protect the tread from moving or being slip-resistant.    (f) At American Walnut LLC on or about April 28, 2014 the steps leading from the log yard area to the log loading platform at the head saw did not have consistent tread height and tread depth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1910.178 L06

Deleted Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 12, 2014
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l):  (a) At American Walnut LLC on or about April 28, 2014 the employer had not certified that each operator had been trained and evaluated on the   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.equipment that they operated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.179 G02 II

Other-than-serious 4 instances 6 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1910.179(g)(2)(ii): Electrical equipment was not protected from dirt, grease, oil, or moisture:    (a) At American Walnut LLC on or about April 28th, 2014 the 2 covers for two 4 X 4 electrical box were hanging loose exposing the wiring and wiring cable to the elements of the weather.    (b) At American Walnut LLC on or about April 28th, 2014 the two covers for the hand held controls for the overhead hoists were damaged and held together by electrical tape.  The controls for the hoist were not protected from the elements of the weather including rain.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4200

1910.219 D01

Serious Gravity 5 3 instances 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,200 · Current $1,050 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a) At American Walnut LLC on or about April 28, 2014 pulleys located at the circular head saw less than 7 feet from the ground were not guarded.    (b) At American Walnut LLC on or about April 28, 2014 had 3 belts and pulleys located at the debarker less than 7 feet from the ground were not guarded.    (c) At American Walnut LLC on or about April 28, 2014 had two pulley and chain combinations just inches from the ground that were not guarded.      NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $4200

1910.219 E01

Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1): Horizontal belts which had both runs 7 feet or less from the floor but more than 42 inches did not have guards that extended to a least fifteen inches above the belt or enclosed by guards conforming to the requirements  specified in 29 CFR1910.219 (m) and (o):  (a) At American Walnut LLC on or about April 28, 2014 a horizontal belts located near the circular head saw that was less than 7 feet from the ground but more than 42" was not guarded.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03

Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3): Vertical and inclined belts were not enclosed by a guard conforming to the standards in paragraphs specified in 29 CFR 1910.219(m) and (o):  (a) At American Walnut LLC on or about April 28, 2014 inclined belts located at the debarker less than 7 feet from the ground were not guarded.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Deleted Serious Gravity 10 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  (a) American Walnut LLC on or about April 28, 2014 had gears and sprockets less than 7 feet from the ground were not guarded.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.303 B01

Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 5, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced

Hazardous substances 8870

29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) At American Walnut LLC on or about April 28, 2014 a 4X4 electrical box had been hit and damaged exposing electrical wiring.  The electrical box damage had not been inspected and removed from service or repaired.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.304 C04

Deleted Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 20, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.304(c)(4): Outside conductors rated 600 volts, nominal, or less did not have a clearance of at least 8 feet from the highest point of roofs over which they pass:  (a) At American Walnut LLC on or about February 19, 2014 and again on or about April 28, 2014 electrical conductors run outside over the roofs of the kilns were less than 8 feet above the roofs.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.305 A02 X

Serious Gravity 5 2 instances 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 12, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced

Hazardous substances 8870

29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:    (a) At American Walnut LLC on or about April 28, 2014 a flexible cord was ran between a metal covered door and the building on the hinge side of the door and was not protected from being cut or crushed in the door opening.    (b) At American Walnut LLC on or about February 19, 2014 and again on or about April 28, 2014 flexible cords were run across areas where people walked in the front lobby and in an office to the east of the front lobby.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.305 G01 IV A

Deleted Serious Gravity 5 1 instance 40 exposed
Issued
Aug 18, 2014
Abate by
Sep 12, 2014
Penalty
Initial $3,500 · Current $0 Reduced

Hazardous substances 8870

29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) At American Walnut LLC on or about February 19, 2014 and again on or about April 28, 2014 electrical power provided to desks was provided by flexible cords instead of with fixed wiring.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM.  FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

View American Walnut LLC's full OSHA safety record →