Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G&S CONSTRUCTION, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G&S CONSTRUCTION, LLC. in LANDMARK INN BED & BREAKFAST, 64 CHESTNUT STREET, COOPERSTOWN, NY 13326 (NAICS 236115). OSHA activity number 339749574.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&S Construction, LLC. — free Get an email when a new federal OSHA severe-injury report for G&S Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
LANDMARK INN BED & BREAKFAST, 64 CHESTNUT STREET
City
COOPERSTOWN
State
NY
ZIP
13326
Mailing
381 COUNTY HIGHWAY 26, COOPERSTOWN, NY 13326
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
5
Ownership type
A

10 citations on file for this inspection.

1926.28 A

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
May 9, 2014
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions:    a) South end of building, on or about 4-30-14:  One employee was cutting "bead board" using a slide miter saw without eye protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1926.403 B02

Deleted Serious Gravity 5 3 instances 3 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a) First floor, on or about 4-30-14:  Employees were operating a 240 volt heater that was plugged into a 4"x 4" box/cord assembly that was not being used as designed or as "listed and labeled".     b) Basement, on or about 4-30-14:  Employees were operating a 240 volt heater that was plugged into a 4"x 4" box/cord assembly that was not being used as designed or as "listed and labeled".     c) Basement, utility room, on or about 4-30-14:  Employees were operating a 240 volt compressor that was plugged into a 2"x 4" box/cord assembly that was not being used as designed or as "listed and labeled".
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.403 I02

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures:    a) Basement, utility room, on or about 4-30-14:  Employees were working in the vicinity of an energized power panel that had no cover on it.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G01 III A

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(1)(iii)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure:     a) Basement, utility room, on or about 4-30-14:  Employees were operating a 240 volt compressor that was plugged into a 2" x 4" box/cord assembly that used job made flexible cord as a substitute for fixed/permanent wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch (2.5cm) wide:    a) South side of building, on or about 4-30-14:  Two employees were working on scaffold systems that were not fully planked, exposing the employees to a fall hazard of 8 feet 6 inches.     b) East side of building, southeast corner, on or about 4-30-14:  Two employees were working on a scaffold that was not fully planked, exposing the employees to a fall hazard of 6 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1926.451 C02

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    a) South and east side of building, on or about 4-30-14:  Two employees were working on scaffold platforms that did not have mud sills under the base plates of the scaffold legs , exposing the employees to a fall hazard of 8 feet 6 inches and 6 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 I

Deleted Serious Gravity 1 2 instances 2 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:    a) South and east side of building, on or about 4-30-14:  Two employees were working on scaffold platforms that were not erected upon level, sound, and rigid footing, exposing the employees to a fall hazard of 8 feet 6 inches and 6 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2014
Abate by
May 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a) South and east side of building, on or about 5-21-13:  Employees were working on scaffold systems that were not inspected by a competent person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1051 A

Deleted Other-than-serious 1 instance 2 exposed
Issued
May 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more:    a) South side of building, on or about 4-30-14:  Two employees were accessing/egressing a porch/deck area to and from the ground that had a change in elevation of 28 inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.1053 B13

Deleted Other-than-serious 2 instances 2 exposed
Issued
May 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:    a) South side of building, on or about 4-30-14:  Two employees were working while standing on the top step of their step ladders.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View G&S Construction, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339749574.