OLDTOWN, ID —
OSHA Inspection: TRI PRO FOREST PRODUCTS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRI PRO FOREST PRODUCTS in 1122 E HIGHWAY 2, OLDTOWN, ID 83822 (NAICS 321912). OSHA activity number 339754426.
Where did this inspection happen?
- Establishment
- TRI PRO FOREST PRODUCTS
- Site address
- 1122 E HIGHWAY 2
- City
- OLDTOWN
- State
- ID
- ZIP
- 83822
- Mailing
- 1122 E HIGHWAY 2, OLDTOWN, ID 83822
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- Employees
- 50
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Jun 3, 2014
- Abate by
- Jul 21, 2014
- Penalty
- Initial $9,800 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not clean and orderly and in a sanitary condition. a) Sawmill Mezzanine: The sawmill mezzanine had not been cleaned adequately to prevent the buildup of wood dust. Wood dust from the mezzanine was assessed as a Class II Dust, and potentially explosive material, according to an OSHA sample taken May 1, 2014. Abatement certification is required for this item. Tri-Pro Forest Products, formerly Tri-Pro Cedar Products, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(1), which was contained in OSHA inspection number 29136, citation number 1, item number 1a and was affirmed as a final order on June 15, 2011, with respect to a workplace located at 1122 E Highway 2, in Oldtown, Idaho.
Recent events (2)
- — I (S) $1200
- — Z (R) $9800
1910.157 E03
- Issued
- Jun 3, 2014
- Abate by
- Jun 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The employer did not assure that portable fire extinguishers are subjected to an annual maintenance check. a) Maintenance Shop - an ABC fire extinguisher had not been subjected to an annual maintenance check since January 2011. Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.215 A04
- Issued
- Jun 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rests were not adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. a) Maintenance Shop - the work rest on a Heavy Duty Black and Decker abrasive wheel grinder was damaged, and was not adjusted to within one-eighth inch of the abrasive wheel. This item was corrected during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.253 B04 III
- Issued
- Jun 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a) Oxygen / Acetylene Storage Area in PB1 - An oxygen cylinder was stored adjacent to an acetylene cylinder and they were not separated by a noncombustible barrier. This item was abated during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G02 II
- Issued
- Jun 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards were not arranged and of such strength as to prevent such damage. a) PB1 Breakdown Lift - Electrical insulation on the 110V cords to the foot pedals of the lift were damaged, and insulation was missing. This item was abated during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 II
- Issued
- Jun 3, 2014
- Abate by
- Jun 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ii): Temporary wiring was not removed immediately upon completion of the project or purpose for which the wiring was installed. a) Security Camera Installation by PB1 - temporary wiring at 110V was not removed immediately after the security camera had been installed. Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at TRI PRO Forest Products
View TRI PRO Forest Products's full OSHA safety record →
More inspections in this industry (NAICS 321912)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339754426.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.