Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: W.E. O'NEIL CONSTRUCTION CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of W.E. O'NEIL CONSTRUCTION CO. in 1130 S. LINCOLN ST, DENVER, CO 80210 (NAICS 236116). OSHA activity number 339756280.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W.E. O'Neil Construction CO. — free Get an email when a new federal OSHA severe-injury report for W.E. O'Neil Construction CO. is published. One employer, no account, unsubscribe in one click.
Site address
1130 S. LINCOLN ST
City
DENVER
State
CO
ZIP
80210
Mailing
229 VALLEGO ST, DENVER, CO 80223
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
1
Ownership type
A

1 citation on file for this inspection.

1926.20 B02

Other-than-serious 2 instances 2 exposed
Issued
May 7, 2014
Abate by
Jun 2, 2014
Penalty
Initial $1,870 · Current $935 Reduced
29 CFR 1926.652(g)(2):  Excavations of earthen material to a level greater than 2 feet (.61m) below the bottom of a shield was permitted:       (a)  W.E. ONeil Construction Co. at 1130 S. Lincoln St, Denver, CO 80210:  On March 17, 2014 the controlling employer did not ensure that subcontractor employees working inside a shield system on the north end of a trench were protected from cave-in.  The depth of the trench was approximately 10 feet.  Sections of soil ranging from 4 feet to 2.7 feet were exposed from the bottom of the shield system to the bottom of the trench.  This condition exposed subcontractor employees to a crushing hazard by trench wall cave-in.       (b)  W.E. ONeil Construction Co. at 1130 S. Lincoln St, Denver, CO 80210:  On March 17, 2014 the controlling employer did not ensure that employees working inside a shield system on the south end of a trench were protected from cave-in.  The depth of the trench was approximately 10 feet.  Sections of soil ranging from 4 feet to 2.7 feet were exposed from the bottom of the shield system to the bottom of the trench.  This condition exposed subcontractor employees to a crushing hazard by trench wall cave-in.
Recent events (2)
  • — I (O) $935
  • — Z (S) $1870

View W.E. O'Neil Construction CO.'s full OSHA safety record →