DEDEDO, GU ·
OSHA Inspection: COST U LESS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COST U LESS in 615 HARMON LOOP RD, DEDEDO, GU 96929 (NAICS 452910). OSHA activity number 339763005.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COST U LESS
- Site address
- 615 HARMON LOOP RD
- City
- DEDEDO
- State
- GU
- ZIP
- 96929
- Mailing
- 265 CHALAN SAN ANTONIO, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452910
- Employees
- 75
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.36 G02
- Issued
- Aug 12, 2014
- Abate by
- Sep 8, 2014
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: a. On May 12, 2014, in the deli produce storage room, the aisle way was completely blocked by boxes of food.
Recent events (2)
- · I (S) $1606.5
- · Z (S) $2295
1910.178 P01
- Issued
- Aug 12, 2014
- Abate by
- Sep 8, 2014
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a. On May 12, 2014, outside the receiving area of the warehouse, the Crown Cascade Sideshifter forklift reverse alarm was not operational and the rear tires were defective.
Recent events (2)
- · I (S) $1606.5
- · Z (S) $2295
1910.305 B01 II
- Issued
- Aug 12, 2014
- Abate by
- Sep 8, 2014
- Penalty
- Initial $2,295 · Current $1,607 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On May 12, 2014, in the electrical room, the electric circuit breaker panel RL was missing a switch panel plug in slot 23 b. On May 12, 2014, in the electrical room, the electric circuit breaker panel SL was missing a switch panel plugs in slots 1, 25, and 29. c. On May 12, 2014, in the electrical room, the electric circuit breaker panel MDP was missing part of a front cover.
Recent events (2)
- · I (S) $1606.5
- · Z (S) $2295
More inspections at Cost U Less
View Cost U Less's full OSHA safety record →
More inspections in this industry (NAICS 452910)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339763005.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.