Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTERN INDUSTRIES, INC. PLASTIC PRODUCTS GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTERN INDUSTRIES, INC. PLASTIC PRODUCTS GROUP in STROTHER FIELD INDUSTRIAL PARK 1ST & B STREET, WINFIELD, KS 67156 (NAICS 326199). OSHA activity number 339765869.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Industries, INC. Plastic Products Group — free Get an email when a new federal OSHA severe-injury report for Western Industries, INC. Plastic Products Group is published. One employer, no account, unsubscribe in one click.
Site address
STROTHER FIELD INDUSTRIAL PARK 1ST & B STREET
City
WINFIELD
State
KS
ZIP
67156
Mailing
PO BOX 746, WINFIELD, KS 67156
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
200
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 24, 2014
Abate by
Jul 21, 2014
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks:  In the machine shop the Grizzly Vertical Mill did not have a guard. Employees were exposed to the hazards of flying chips and/or contacting the rotating chuck.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.303 F02

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 24, 2014
Abate by
Jul 21, 2014
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  1.    In the Big Building  Panel B breakers 7, 9, 11, 13, 15 17 and 20 were not labeled. Breakers 12, 14 , 16 and 18 were not labeled on the Legend but did have partial labels on the panel cover. Breakers 19 and 21 had conflicting labels on two different locations. Breakers 23 and 25 had conflicting labels on two different locations.  2.    In the Big Building  Panel D breakers 31 through 42 were not labeled on the Legend. 3.  In the West Building an unidentified breaker panel on the east wall of the South Facility had the Legend of Breakers missing and the labeling located on the panel itself was incomplete and/or illegible.  Employees were exposed to electrical shock and/or struck-by/caught between hazards.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.303 F03

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 24, 2014
Abate by
Jul 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(3): The markings required by paragraphs (f)(1) and (f)(2) of 29 CFR 1910.303 were not sufficiently durable to withstand the environment involved:  1. In the Big Building Panel B and Panel D breakers were not labeled in a manner that was durable and legible.   2. In the West Building an unidentified breaker panel on the east wall of the South Facility did not have the breakers labeled in a manner that was durable and legible.  Employees were exposed to a shock hazard and/or a struck-by/caught between hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 24, 2014
Penalty
Initial $1,951 · Current $1,366 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    In the East Building at Blow Molding Machine 2, Conveyer C-17 was being provided electrical power via a yellow AWG-12 extension cord. Employees were exposed to a potential shock hazard.
Recent events (2)
  • — I (S) $1365.7
  • — Z (S) $1951

View Western Industries, INC. Plastic Products Group's full OSHA safety record →