OSHA Inspection: TELLA TOOL & MFG. CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TELLA TOOL & MFG. CO. in 1015 N. RIDGE AVE., LOMBARD, IL 60148 (NAICS 332116). OSHA activity number 339769143.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tella Tool & MFG. CO. — free Get an email when a new federal OSHA severe-injury report for Tella Tool & MFG. CO. is published. One employer, no account, unsubscribe in one click.
Site address
1015 N. RIDGE AVE.
City
LOMBARD
State
IL
ZIP
60148
Mailing
1015 N. RIDGE AVENUE, LOMBARD, IL 60148
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332116
Employees
103
Ownership type
A

6 citations on file for this inspection.

1910.335 A01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 26, 2014
Abate by
Jul 31, 2014
Penalty
Initial $4,500 · Current $3,000 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:    1015 N. Ridge Ave. bldg., North Press and South Press departments: employer did not provide adequate electrical protective equipment for employees exposed to contact with live parts hazard during line voltage testing on 480V energized electrical control circuits to protect against electrical shock, burns, and Arc flash/blast injuries:    a) Rubber insulating gloves with leather protectors.  b) Arc-Rated clothing such as arc-rated long-sleeve shirt and pants, or arc-rated coverall.  c) Arc-Rated flash suit, hood or arc-rated face shield and arc-rated balaclava.  d) Hearing protection (canal inserts).    Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).    Abatement Note: For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4500

1910.335 A01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 26, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(iv): Employees exposed to the danger of head injury from electric shock or burns due to contact with exposed energized parts did not wear nonconductive head protection:  1015 N. Ridge Ave. bldg., North Press and South Press departments: employer did not provide adequate nonconductive head protection such as hard hats with die-electric properties, for employees exposed to contact with live parts hazard during line voltage testing on 480V energized electrical control circuits to protect against electrical shock, burns, and Arc flash/blast injuries:  Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).  Abatement Note: For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 V

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 26, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face:  1015 N. Ridge Ave. bldg., North Press and South Press departments: employer did not provide adequate electrical protective equipment such as arc-flash rated face shield to prevent burns or injury from flying debris in the event of an Arc flash/blast for employees exposed to contact with live parts hazard during line voltage testing on 480V energized electrical control circuits.   Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).  Abatement Note: For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Repeat Gravity 5 1 instance 6 exposed
Issued
Jun 26, 2014
Penalty
Initial $9,000 · Current $6,965 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    245 Cortland Ave. Bldg., North, CNC Machining, Super B350 Mach 1070 metal cutting saw: on or about May 16, 2014, employees cutting aluminum and carbon steel raw bar stock into smaller pieces were exposed to contact with rotating blade amputation and laceration hazards because required adequate guarding was not provided.    There is no abatement certification or documentation required for this item.    The Tella Tool & Mfg. Co. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 110535, citation number 01, item number 003 and was affirmed as a final order on 5/07/2012, with respect to a workplace located at 1015 N. Ridge Ave., Lombard, IL 60148.
Recent events (2)
  • — I (R) $6965
  • — Z (R) $9000

1910.212 A03 II

Repeat Gravity 10 3 instances 3 exposed
Issued
Jun 26, 2014
Abate by
Dec 31, 2014
Penalty
Initial $12,600 · Current $7,000 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    1015 N. Ridge Ave. Bldg., South, Press Brakes, Beyeler Mach-0935, Wysong Mach-0707, Wysong Mach-0750 hydraulic press brakes: on or about May 15, 2014, employees bending and forming metal parts were exposed to caught in-between amputation hazard where adequate point of operation guarding systems or methods were not provided.    Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).    The Tella Tool & Mfg. Co. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 110535, citation number 01, item number 002 and was affirmed as a final order on 5/07/2012, with respect to a workplace located at 1015 N. Ridge Ave., Lombard, IL 60148.
Recent events (2)
  • — I (R) $7000
  • — Z (R) $12600

1910.147 C04 II B

Other-than-serious 1 instance 16 exposed
Issued
Jun 26, 2014
Abate by
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  1015 N. Ridge Ave. bldg., North and South Press, part-revolution mechanical power presses: on May 15, 2014, employer's established lockout/tagout machine-specific procedures did not correctly assess all present hazardous energy sources, and did not identify specific steps and methods for proper shut down, isolating, blocking and securing machines or equipment to control hazardous energy sources.   Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tella Tool & MFG. CO.'s full OSHA safety record →