Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PALMER PLASTICS, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of PALMER PLASTICS, INC. in 2906 WILLIAM PENN HWY, SUITE 505, EASTON, PA 18045 (NAICS 326199). OSHA activity number 339770638.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Palmer Plastics, INC. — free Get an email when a new federal OSHA severe-injury report for Palmer Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2906 WILLIAM PENN HWY, SUITE 505
City
EASTON
State
PA
ZIP
18045
Mailing
2906 WILLIAM PENN HWY, SUITE 505, EASTON, PA 18045
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 31, 2014
Penalty
Initial $1,496 · Current $1,122 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)  Palmer Plastics - Employees were exposed to in-running nip point hazards of rotating pulleys of a power transmission device used to power a silo discharge auger, on or about June 11, 2014.  No abatement documentation required.  Corrected during inspection.
Recent events (2)
  • — I (S) $1122
  • — Z (S) $1496

1910.219 E03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(ii): All guards for inclined belts were not arranged in such a manner that a minimum clearance of seven (7) feet is maintained between belt and floor at any point outside of guard.  a)  Palmer Plastics - Employees were exposed to in-running nip point hazards of a rotating power transmission belt used to power a silo discharge auger, on or about June 11, 2014.  No abatement documentation required.  Corrected during inspection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 K02

Serious Gravity 5 3 instances 8 exposed
Issued
Jul 31, 2014
Penalty
Initial $1,496 · Current $1,122 Reduced

Hazardous substances 81108111

29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program:  a) Palmer Plastics - A Machine Operator feeding the conveyor of the new #6 Grinder was exposed to continuous noise at 154.7% of the permissible exposure limitl of 90 dBA or an eight-hour time weighted average of 93.1 dBA.  This exposure was observed over a 473 minute sampling period. A zero exposure level was assumed for the 7 minutes not sampled. The employer did not conduct annual noise training for those employees exposed over the action level of 85 dBA observed on or about May 15, 2014.     b)  Palmer Plastics - A Machine Operator operating the vacuum hose for #2 Grinder was exposed to continuous noise at 111.6% of the permissible exposure limit of 90 dBA or an eight-hour time weighted average of 90.8 dBA.  This exposure was observed over a 470 minute sampling period. A zero exposure level was assumed for the 10 minutes not sampled.  The employer did not conduct annual noise training for those employees exposed over the action level of 85 dBA observed  on or about May 15, 2014.     c)  Palmer Plastics - A Machine Operator operating the extruder was exposed to continuous noise at 79.3% of the permissible exposure limit of 90 dBA or an eight-hour time weighted average of 88.5 dBA.  This exposure was observed over a 455 minute sampling period.  A zero exposure level was assumed for the 25 minutes not sampled.The employer did not conduct annual noise training for those employees exposed over the action level of 85 dBA on or observed on or about May 15, 2014.    No abatement documentation required.