EASTON, PA —
OSHA Inspection: PALMER PLASTICS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PALMER PLASTICS, INC. in 2906 WILLIAM PENN HWY, SUITE 505, EASTON, PA 18045 (NAICS 326199). OSHA activity number 348429648.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALMER PLASTICS, INC.
- Site address
- 2906 WILLIAM PENN HWY, SUITE 505
- City
- EASTON
- State
- PA
- ZIP
- 18045
- Mailing
- 2906 WILLIAM PENN HWY, SUITE 505, EASTON, PA 18045
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A01
- Issued
- Jan 30, 2026
- Abate by
- Feb 19, 2026
- Penalty
- Initial $2,412 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: a) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, in the Cumberland Grinder machine area and throughout the facility, on or about August 11, 2025 - the employer failed to ensure that the working surface in and around the plant was clean and orderly. Employees exposed to slip, trips, and fall due to excessive amounts of plastic dust on the walking working surface. b) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, on the Vecoplan Shredder Machine elevated platform, on or about August 11, 2025 - the employer failed to ensure that the working surface on an elevated platform was clean and orderly. Employees, feeding the Vecoplan Shredder Machine, were exposed to slip, trip, and fall hazard due to debris and extraneous material on the platform. c) 2906 William Penn Hwy, Suite 505, Easton, PA 18045, in the baler area, on or about August 11, 2025 - the employer failed to ensure that the working surface in front of a bailer was clean and orderly. Employees were exposed to a trip hazard due to a steel plate covering a shallow section of missing concrete that was not secured to the surface.
Recent events (2)
- — I (O) $1300
- — Z (S) $2412
1910.29 B10
- Issued
- Jan 30, 2026
- Penalty
- Initial $2,050 · Current $1,811 Reduced
General-duty citation text
29 CFR 1910.29(b)(10): The employer did not ensure that when guardrail systems are used at hoist areas, a removable guardrail section, consisting of a top rail and midrail, are placed across the access opening between guardrail sections when employees are not performing hoisting operations. The employer may use chains or gates instead of a removable guardrail section at hoist areas if the employer demonstrates the chains or gates provide a level of safety equivalent to guardrails: a) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, on or about August 11, 2025 - The employer utilized chains instead of a removable guardrail section at fork lift loading area. The employer did not demonstrate the chains provided a level of safety equivalent to guardrails. Exposing employees, operating a Cumberland Grinder machine, to a fall hazard from approximately 6 ft in height. b) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, on or about August 11, 2025 - The employer utilized chains instead of a removable guardrail section at fork lift loading area. The employer did not demonstrate the chains provided a level of safety equivalent to guardrails. Exposing employees accessing the Vecoplan Shredder Platform, to a fall hazard from approximately 6 ft in height.
Recent events (2)
- — I (S) $1811
- — Z (S) $2050
1910.303 B02
- Issued
- Jan 30, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, next to the Dynisco Extrusion pelletizer, on or about August 11, 2025 - electrical tape was used to attempt to fix a cut in the power cord to the machine control panel. Electrical tape was not used or installed in accordance with instructions included in the listing or labeling, exposing employees to shock hazard. b) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, next to the Dynisco Extrusion pelletizer, on or about August 11, 2025 - equipment was not used or installed in accordance with instructions included in the listing or labeling. Employees exposed to shock and burns due to a 460 volt electrical panels having a broken panel box door lock. Employer utilized a piece of rope to attempt to hold the panel door shut.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Jan 30, 2026
- Penalty
- Initial $339 · Current $250 Reduced
General-duty citation text
29 CFR 1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) 2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, next to the Cumberland Grinder, on or about August 11, 2025 - Sufficient access and working space was not provided and maintained about all electric equipment. Employees exposed to electrical shock and burns due to electrical panels and disconnects were obscured by garbage and debris. b)2906 WILLIAM PENN HWY, SUITE 505 EASTON, PA 18045, behind the PPK Grinder, on or about August 11, 2025 - Sufficient access and working space was not provided and maintained about all electric equipment. Employees exposed to electrical shock and burns due to electrical panels and disconnects were obscured by pallets and debris.
Recent events (2)
- — I (O) $250
- — Z (O) $339
More inspections at Palmer Plastics, INC.
View Palmer Plastics, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348429648.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.