TAMUNING, GU —
OSHA Inspection: CORE TECH INTERNATIONAL INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CORE TECH INTERNATIONAL INC in SUMMERVILLE RESIDENTIAL PROJECT, BLDG. B, TAMUNING, GU 96913 (NAICS 236220). OSHA activity number 339771313.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORE TECH INTERNATIONAL INC
- Site address
- SUMMERVILLE RESIDENTIAL PROJECT, BLDG. B
- City
- TAMUNING
- State
- GU
- ZIP
- 96913
- Mailing
- 388 S MARINE DRIVE SUITE 400,, TAMUNING, GU 96913
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.350 A09
- Issued
- Aug 1, 2014
- Penalty
- Initial $1,517 · Current $1,517
General-duty citation text
29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times: a. This violation occurred on May 14, 2014, at the break tent area, a compressed oxygen cylinder not secured.
Recent events (1)
- — Z (S) $1517
1926.404 B01 I
- Issued
- Aug 1, 2014
- Penalty
- Initial $1,517 · Current $1,517
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a. On May 14, 2014 at the west side of the break tent area, the yellow cord providing power to the Wacker mixer/vibrator was used without a ground fault circuit interrupter exposing employees to electrical hazards.
Recent events (1)
- — Z (S) $1517
More inspections at Core Tech International INC
View Core Tech International INC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339771313.