FREDONIA, NY —
OSHA Inspection: THE TUBE FABRICATION COMPANY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THE TUBE FABRICATION COMPANY, INC. in 183 EAST MAIN STREET, FREDONIA, NY 14063 (NAICS 331210). OSHA activity number 339771701.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE TUBE FABRICATION COMPANY, INC.
- Site address
- 183 EAST MAIN STREET
- City
- FREDONIA
- State
- NY
- ZIP
- 14063
- Mailing
- 183 EAST MAIN STREET, FREDONIA, NY 14063
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Sep 26, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the production area, the pulleys and belts on the Brass Annealer were not guarded to protect in going nip points. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $1200
1910.213 A09
- Issued
- Sep 26, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requires of 1910.219: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the belt(s) and pulleys on the joiner/planer were not guarded from accidental contact. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $1200
1910.213 B03
- Issued
- Sep 26, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the Delta table saw was not equipped with a drop out or similar device to prevent unexpected start up following power outages. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $1200
1910.213 J03
- Issued
- Sep 26, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.213(j)(3): Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the guard on the joiner/planer did not automatically adjust or return to cover the cutting head. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (S) $1200
1910.303 B02
- Issued
- Sep 26, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the production area, a 4"x4" box with pre-punched knockouts was hung from a flexible cable to create a pendent box. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (O) $0
1910.304 G05
- Issued
- Sep 26, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the power cord for the joiner/planer was missing the ground prong. ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
- — Z (O) $0
More inspections at The Tube Fabrication Company, INC.
View The Tube Fabrication Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331210)
More inspections in NY
Source