Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TECH CAST, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TECH CAST, LLC in 640 SOUTH CHERRY STREET, MYERSTOWN, PA 17067 (NAICS 331512). OSHA activity number 339772279.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tech Cast, LLC — free Get an email when a new federal OSHA severe-injury report for Tech Cast, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TECH CAST, LLC
Site address
640 SOUTH CHERRY STREET
City
MYERSTOWN
State
PA
ZIP
17067
Mailing
640 SOUTH CHERRY STREET, MYERSTOWN, PA 17067
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331512
Employees
100
Ownership type
A

4 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 19 exposed
Issued
Jul 18, 2014
Abate by
Aug 13, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed.  Materials or equipment were placed permanently or temporarily within the exit route:  a) Wax Room - Employees exiting along the emergency exit route were exposed to burn hazards from an uncovered portable vat of Cerita Stick Tight heated to approximately 300 degrees Fahrenheit, on or about May 16th, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.212 A01

Serious Gravity 1 1 instance 19 exposed
Issued
Jul 18, 2014
Penalty
Initial $1,339 · Current $1,004 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Wax Room - Employees cutting wax on a 17 inch band saw Model "G0513P" were exposed to a point of operation hazards from a missing guard, on or about May 16th, 2014.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1004.25
  • — Z (S) $1339

1910.242 B

Serious Gravity 1 3 instances 3 exposed
Issued
Jul 18, 2014
Penalty
Initial $1,339 · Current $1,004 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 psi:  a) Wax Room Machine 4 - Employees blowing off matter were exposed to struck-by hazards from a compressed air gun with a PSI of approximately fifty (50) psi, on or about May 16th, 2014.  b) Wax Room Machine 6a - Employees blowing off matter were exposed to struck-by hazards from a compressed air gun with a PSI of approximately ninety (90) psi, on or about May 16th, 2014.  c) Wax Room Machine 7 - Employees blowing off matter were exposed to struck-by hazards from a compressed air gun with a PSI of approximately one hundred (100) psi, on or about May 16th, 2014.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1004.25
  • — Z (S) $1339

1910.304 F01 VIII

Other-than-serious 1 instance 1 exposed
Issued
Jul 18, 2014
Abate by
Aug 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD":  a) Wax Room Circuit Breaker 37 - Employees turning off the lights are exposed to a shock hazard from old breakers which are not listed and marked "SWD", on or about May 16th, 2014.  b)Wax Room Circuit Breaker 39 - Employees turning off the lights are exposed to a shock hazard from old breakers which are not listed and marked "SWD", on or about May 16th, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Tech Cast, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339772279.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.