ELYSBURG, PA —
OSHA Inspection: CATAWISSA WOOD AND COMPONENTS, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CATAWISSA WOOD AND COMPONENTS, INCORPORATED in 1015 WEST VALLEY AVENUE, ELYSBURG, PA 17824 (NAICS 321912). OSHA activity number 339775900.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CATAWISSA WOOD AND COMPONENTS, INCORPORATED
- Site address
- 1015 WEST VALLEY AVENUE
- City
- ELYSBURG
- State
- PA
- ZIP
- 17824
- Mailing
- 1015 WEST VALLEY AVENUE, ELYSBURG, PA 17824
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- Employees
- 67
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.23 C01
- Issued
- Jul 22, 2014
- Abate by
- Aug 9, 2014
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. a) Incoming Grading Area, 1510 West Valley Avenue, Elysburg, PA - Employees worked on an open-sided platform without guarding between the platform and the machinery while stacking wood with the Automated Lumber Handling, Inc. equipment. Employees were exposed to a four-foot, seven-inch (4'7") fall hazard from the open-sided platform to the concrete floor, as observed on or about May 20, 2014. b) Incoming Grading Area, 1510 West Valley Avenue, Elysburg, PA - Employees worked on an open-sided platform without guarding between the access stairway and the machinery while stacking wood with the Automated Lumber Handling, Inc. equipment. Employees were exposed to a four-foot, seven-inch (4'7") fall hazard from the open-sided platform to the concrete floor, as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.147 D03
- Issued
- Jul 22, 2014
- Abate by
- Aug 9, 2014
- Penalty
- Initial $3,500 · Current $2,625 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a) Finish Department, 1510 West Valley Avenue, Elysburg, PA - Employees changed the tooling on the Mereen-Johnson Gang Rip Saw Model No. 424-DCS (Serial No. MJ-5571) without stopping electrical power to the machine by placing the knife switch at the electrical disconnect into the closed position. Employees were exposed to struck-by and/or caught-in hazards, as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $2625
- — Z (S) $3500
1910.147 D04 I
- Issued
- Jul 22, 2014
- Abate by
- Aug 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees. a) Finish Department, 1510 West Valley Avenue, Elysburg, PA - Employees changed the tooling on the Mereen-Johnson Gang Rip Saw Model No. 424-DCS (Serial No. MJ-5571) without placing a lockout device on the electrical disconnect knife switch for the rip saw. Employees were exposed to struck-by and/or caught-in hazards, as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jul 22, 2014
- Abate by
- Aug 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Finish Department, 1510 West Valley Avenue, Elysburg, PA - The employer did not conduct an inspection of the energy control procedures at least annually as the last audit had been conducted on January 21, 2013. Employees were exposed to machines unexpectedly energizing, starting-up, or releasing stored energy, on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Jul 22, 2014
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Rough End Department, 1510 West Valley Avenue, Elysburg, PA - Employees used a portable clamp-on light without a bulb guard attached to an extension cord (flexible power cord) to provide illumination when performing inspection work. Employees were exposed to contact with an electrical current hazard on or about May 20, 2014. b) Rough End Department, 1510 West Valley Avenue, Elysburg, PA - Employees used a power strip (relocatable power tap-RPT) attached to an extension cord (flexible power cord) to provide electrical power to electrical equipment. Employees were exposed to contact with an electrical current hazard on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. The hazardous conditions were corrected during the inspection.
Recent events (2)
- — I (S) $2100
- — Z (S) $2800
1910.303 B07 IV
- Issued
- Jul 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating. a) Finish Department, 1510 West Valley Avenue, Elysburg, PA - Employees used a Lenze AC Tech SMVector frequency inverter with a power cord that had exposed conductors carrying electrical current. Employees were exposed to contact with an electrical current hazard on or about May 22, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation. b) Rough End Department, 1510 West Valley Avenue, Elysburg, PA - Employees used a metal frame roller conveyor that was provided electrical power through a conduit and dislodged compression fitting that exposed conductors carrying electrical current. Employees were exposed to contact with an electrical current hazard as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 II
- Issued
- Jul 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: a) Finish Department, 1510 West Valley Avenue, Elysburg, PA - Employees that used The Original Radial Arm Saw Model No. 3546 (Serial No. 011101063) worked directly beneath a light fixture that was six-foot, four-inches (6'4") above ground level Employees were exposed to struck-by and contact with electrical current hazards due to the lack of bulb guards on the lights, on or about May 20, 2014. b) Finish Department, 1510 West Valley Avenue, Elysburg, PA - Employees working with the glue press worked directly beneath light fixtures that were six-foot, six-inches (6'6") above ground level. Employees were exposed to struck-by and contact with electrical current hazards due to the lack of bulb guards, as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 F01 IV
- Issued
- Jul 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel. a) Finish Department, 1015 West Valley Avenue, Elysburg, PA - Employee access to an overcurrent device (electrical panel) for the Wisconsin Vector-4 Tennoner Jump Score Saw was blocked by wooden boxes and stacks of wood. Employees were exposed to slips, trips and falls and the hazards associated with being unable to de-energize equipment in the event of an emergency, as observed on or about May 20, 2014. b) Rough End Department, 1015 West Valley Avenue, Elysburg, PA - Employee access to an overcurrent device (electrical panel) for the Mereen Johnson Model 431-DC Gang Rip Saw was blocked by stacks of wood. Employees were exposed to slips, trips and falls and the hazards associated with being unable to de-energize equipment in the event of an emergency, as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) Finish Department, 1510 West Valley Avenue, Elysburg, PA - Employees used an extension cord (flexible power cord) to provide electrical power to a Carter Products Helium/Neon Laser Guideline Laser Model No. LGL100A5 continuously for twenty-one (21) years. Employees were exposed to contact with an electrical current hazard on or about May 20, 2014. b) Rough End Department, 1510 West Valley Avenue, Elysburg, PA - Employees used an extension cord (flexible power cord) to provide electrical power to an array of fourteen (14) various models of Carter Products Laser Guideline Lasers continuously for three (3) years, as observed on or about May 20, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. The hazardous condition was corrected during the inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 S06
- Issued
- Jul 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards. b) Finish Department, 1015 West Valley Avenue, Elysburg, PA - Wood dust from the operation of a Mattison 404 Straight Line Saw had accumulated on the floor, an electrical power cord for a fan, and an extension cord. Employees were exposed to a fire hazard that could be created by the ignition of the wood dust by sparks upon connecting the electrical power cord to the extension cord, as observed on or about May 20, 2012. b) Finish Department, 1015 West Valley Avenue, Elysburg, PA - Wood dust from the operation of a Timesaver Abrasive Planer had accumulated on the floor, electrical power cord, and electrical outlet receptacle. Employees were exposed to a fire hazard that could be created by the ignition of the wood dust by sparks from turning on/off equipment, as observed on or about May 20, 2012. In accordance with 29 CFR 1903.19(c), abatement certification is not required for this violation. The hazard was corrected during the inspection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Catawissa Wood and Components, Incorporated
View Catawissa Wood and Components, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 321912)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339775900.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.