MILTON, MA ·
OSHA Inspection: NORMAN F. BURNS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NORMAN F. BURNS in 390 BROOK ROAD, MILTON, MA 02186 (NAICS 238160). OSHA activity number 339777088.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORMAN F. BURNS
- Site address
- 390 BROOK ROAD
- City
- MILTON
- State
- MA
- ZIP
- 02186
- Mailing
- 86 GARDNER STREET, ROCKLAND, MA 02370
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1926.102 A01
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: Location: Jobsite Employees were exposed to struck by hazards from flying debris, while using a pneumatic nail gun, and were not protected by safety glasses.
Recent events (1)
- · Z (S) $1600
1926.451 B01
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): Location: Jobsite Employees were exposed to fall hazards greater than 10 feet, while working from a carpenters bracket scaffold, where the scaffold platform was not fully planked or decked between the front uprights.
Recent events (1)
- · Z (S) $2800
1926.451 G01
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Location: Jobsite Employees were exposed to a fall hazard of greater than 10 feet, while working from a carpenters bracket scaffold, where no guardrail systems, end rail systems, or personal fall arrest systems were used or provided.
Recent events (1)
- · Z (S) $0
1926.501 B13
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: Jobsite Employees were exposed to fall hazard of greater than 6 feet to the ground below, while working where fall protection had not been used or provided. Instance 1) Employees were accessing a carpenters scaffold on the second floor through a wall opening, where no fall protection was used or provided. No guardrails were installed, and no personal fall arrest system was used. Instance 2) An employee was exposed to a fall hazard greater than 6 feet at an unguarded first floor wall opening, at the back entrance of the building under construction. Instance 3) An employee was exposed to a fall greater than 6 feet to the basement below, where the floor opening was not completely covered.
Recent events (1)
- · Z (S) $2800
1926.502 I03
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees: Location: Jobsite Employees were exposed to falls greater than 6 feet, while working, where a floor cover was not secured to prevent accidental displacement.
Recent events (1)
- · Z (S) $0
1926.502 I04
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: Location: Jobsite Employees were exposed to fall hazards, while working on and around a covered floor opening, where the cover was not marked with the word "HOLE" or "COVER" to provide warning of the hazard.
Recent events (1)
- · Z (S) $0
1926.1051 A
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: Location: Jobsite Employees were exposed to trips and falls while working, where a stairway or ladder was not provided at a personnel access point greater than 19 inches in height.
Recent events (1)
- · Z (S) $1200
1926.404 F06
- Issued
- Aug 19, 2014
- Abate by
- Oct 8, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: Jobsite Employees were exposed to electric shock while using an extension cord plugged into a radio, which was lacking a grounding pin.
Recent events (1)
- · Z (O) $0
More inspections at Norman F. Burns
View Norman F. Burns's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339777088.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.