Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PARAMON CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PARAMON CONSTRUCTION LLC in 20230 TESSARO DRIVE, VENICE, FL 34293 (NAICS 238130). OSHA activity number 339789810.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paramon Construction LLC for free Get an email when a new federal OSHA severe-injury report for Paramon Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
20230 TESSARO DRIVE
City
VENICE
State
FL
ZIP
34293
Mailing
1535 TINA LANE, KISSIMMEE, FL 34744
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
100
Ownership type
Private (A)

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 28, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) For employees working at 20230 Tessaro Drive #213 in North Port, as observed on or about 29 May, 2014. Employees were observed installing plywood sheathing on a roof with a 5:12 pitch. The eave to ground height was approximately 10 feet and the employees had no fall protection system in place.
Recent events (1)
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) For employees working at 20230 Tessaro Drive in North Port, as observed on or about 29 may, 2014. Employees using an extension ladder to access the upper landing surface did not have the ladder extended far enough above the upper landing surface. The extension ladder only extended approximately 12 inches above the upper landing surface.
Recent events (1)
  • · Z (S) $0

1926.405 G02 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 28, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a) For employees working at 20230 Tessaro Drive in North Port, as observed on or about 29 may, 2014. Employees were using power tools that were supplied power through extension cords that were missing strain relief. The outer insulation on the extension cords in use which provides strain relief was pulled away from the plug end.
Recent events (1)
  • · Z (S) $2800

1926.403 B02

Other-than-serious 2 instances 4 exposed
Issued
Jul 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) For employees working at 20230 Tessaro Drive in North Port, as observed on or about 29 May, 2014. Employees were using relocatable power taps to supply power to the power tools in operation. Two relocatable power taps were in use to increase the number of available outlets on the branch circuit.
Recent events (1)
  • · Z (O) $0

1926.404 F06

Other-than-serious 2 instances 4 exposed
Issued
Jul 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a) For employees working at 20230 Tessaro Drive in North Port, as observed on or about 29 may, 2014. Employees were using power tools that were supplied power through extension cords that were missing the ground prongs. The extension cords in use did not have a permanent and continuous path to ground.
Recent events (1)
  • · Z (O) $0

View Paramon Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339789810.