Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GC CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GC CONSTRUCTION in 644 H STREET NE, WASHINGTON, DC 20010 (NAICS 238130). OSHA activity number 339790891.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GC Construction — free Get an email when a new federal OSHA severe-injury report for GC Construction is published. One employer, no account, unsubscribe in one click.
Establishment
GC CONSTRUCTION
Site address
644 H STREET NE
City
WASHINGTON
State
DC
ZIP
20010
Mailing
9201 GILMOREDR, LORTON, VA 22079
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.403 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 7, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) On May 28, 2014 and at times prior thereto; second floor; employees were working around a damaged energized electrical box that was not installed and used in accordance with the instructions included in the listing, labeling, or certification. According with the manufacturer, these boxes are designed to be mounted on or in the wall.
Recent events (1)
  • — Z (S) $2800

1926.405 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:   a) On May 28, 2014 and at times prior thereto; second floor; employees were using unguarded energized outlets either plugged in directly or by portable extension cords to power electrical such as but not limited to saws.
Recent events (1)
  • — Z (S) $0

1926.404 B01 II

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 7, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.  a) On May 28, 2014 and at times prior thereto; Third floor; employees were using portable electrical equipment, such as but not limited to circular saws, that were plugged into outlets either directly or by portable extension cords which were not equipped with a ground fault circuit interrupter.
Recent events (1)
  • — Z (S) $1600

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
Aug 7, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On May 28, 2014 and at times prior thereto; roof area; employee was working on the roof removing water that had collected in the blue tarp without a personal fall arrest system in place to prevent him from falling 35 feet to ground level.    b) On May 28, 2014 and at times prior thereto; third floor; employees framing the residential home were observed working near unguarded floor openings exposing them to a fall hazard to the lower levels; 10-20 foot fall.     c) On May 28, 2014 and at times prior thereto; third floor; employees framing the residential home were working around unguarded wall openings exposing them to 10-20 foot fall to the lower levels.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 7, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed   a) On May 28, 2014 and at times prior thereto; second floor; the ladder used to access the work area was set flush to the working platform exposing them to a fall hazard of 12 feet to ground level while accessing or stepping off the ladder to the platform.
Recent events (1)
  • — Z (S) $2000

View GC Construction's full OSHA safety record →