BOISE, ID ·
OSHA Inspection: YOUNG'S HEAVY EQUIPMENT
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of YOUNG'S HEAVY EQUIPMENT in 203 EAST AMITY, BOISE, ID 83702 (NAICS 339999). OSHA activity number 339793549.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YOUNG'S HEAVY EQUIPMENT
- Site address
- 203 EAST AMITY
- City
- BOISE
- State
- ID
- ZIP
- 83702
- Mailing
- 203 E AMITY, BOISE, ID 83702
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 5
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.107 C04
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.107(c)(4): Electrical wiring and equipment did not conform to the provisions of this paragraph and were otherwise not in accordance with subpart S of this part: a) Spray area(s): Electrical wiring was spliced. This includes but is not limited to the fluorescent light fixtures. Note) Abatement certification IS required for these items.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.107 C07
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(7): Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated by a partition, were not totally enclosed to prevent the falling of hot particles and not protected from mechanical injury by suitable guards or by location: a) Spray areas: Polyurethane paints and/or organic vapors accumulated on the vertically positioned fluorescent light fixtures that were installed along each spray area wall. The light fixtures were not covered or otherwise protected from damage. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.304 G05
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Spray areas: Electrical plugs were missing grounding plugs. This includes but is not limited to the fluorescent light fixtures. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 A02 X
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a) Near future blasting area: An extension cord strung across a walkway/driveway was damaged. The cord was used for power to the break room. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a) Break room: An extension cord was used for power to the employee break room. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.242 A
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.242(a): Each employer did not take responsibility for the safe condition of tools and equipment used by employees, including tools and equipment which may be furnished by employees: a) Outdoor blasting area: Whip check safety pins were not in place to secure the air hoses which supplied pressurized air for the abrasive blasting operations. b) Future covered blasting area: A hand held skilsaw had a damaged power cord. Note) Abatement certification IS NOT required for instance (a). Note) Abatement certification IS required for instance (b).
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.244 B
- Issued
- Jul 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(b): The blast cleaning nozzles were not equipped with an operating valve which must be held open manually. A support was not provided on which the nozzle may be mounted when it is not in use: a) Outdoor abrasive blasting area: The "dead man" switch on the hand-held blasting nozzle used with the Clemco Blast Cleaning Machine, was disabled. Note) Abatement certification IS NOT required for this item.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.157 C01
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not provide portable fire extinguishers and did not mount, locate and identify them so that they were readily accessible to employees without subjecting the employees to possible injury: a) Spraying areas: Portable fire extinguishers were not readily available to employees working in the spray areas, in that they were covered in black paint, not mounted or identified in any way. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.157 E01
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(1): The employer did not require the inspection, maintenance and testing of all portable fire extinguishers in the workplace: a) Spraying areas: Portable fire extinguishers did not have current inspection tags. b) Spraying areas: Portable fire extinguishers were covered with black paint and were not able to be seen or readily accessed by employees working in the spray areas. Note) Abatement certification IS required for these items.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 L06
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l): a) Employees with previous training and experience on forklift operations were not evaluated and certified by the employer to ensure the previous training and experience would be adequate for their current environment, the forklift, and materials to be handled. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.253 B04 III
- Issued
- Jul 18, 2014
- Abate by
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Storage trailer: Compressed gas cylinders and fuel-gas cylinders were stored together inside a walk-in storage container. Note) Abatement certification IS required for this item.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Young'S Heavy Equipment
View Young'S Heavy Equipment's full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339793549.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.