Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: THE TIMKEN COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THE TIMKEN COMPANY in 2325 E. MANSFIELD RD., BUCYRUS, OH 44820 (NAICS 332991). OSHA activity number 339794570.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Timken Company for free Get an email when a new federal OSHA severe-injury report for The Timken Company is published. One employer, no account, unsubscribe in one click.
Establishment
THE TIMKEN COMPANY
Site address
2325 E. MANSFIELD RD.
City
BUCYRUS
State
OH
ZIP
44820
Mailing
P.O. BOX 391, BUCYRUS, OH 44820
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332991
Employees
277
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 2 instances 62 exposed
Issued
Sep 5, 2014
Abate by
Aug 31, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a.) The Timken Company located at 2325 E. Mansfield Rd. Bucyrus, OH 44820; On or about June 3, 2014, an employee was exposed to a crush injury while clearing misaligned parts on the 9-Line cone automatic assembler without utilizing the energy control procedure.  he employee sustained a crush injury to the right hand from a pneumatic ram which was not deenergized.  The work performed by the employee (clearing of the misaligned parts) was not a minor tool change or adjustment within the lockout exception, and so energy control procedures were required.    b.) The Timken Company located at 2325 E. Mansfield Rd. Bucyrus, OH 44820; On or about June 3, 2014, the employer did not ensure employees utilized energy control procedures when entering the 5 Line assembly area to remove and replace nest assemblies.  Removing and replacing nest assemblies for purpose of making adjustments are not minor tool changes or adjustments within the lockout exception, and so energy control procedures were required.
Recent events (3)
  • · F (S) $4900
  • · C (S) $7000
  • · Z (S) $7000

1910.147 D03

Deleted Serious Gravity 10 2 instances 62 exposed
Issued
Sep 5, 2014
Abate by
Oct 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  a.) The Timken Company located at 2325 E. Mansfield Rd. Bucyrus, OH 44820; On or about June 3, 2014, the employer did not ensure that energy isolating devices needed to control hazardous energy of the 9 Line assembly press were operated, so as to isolate hazardous energy sources while employees cleared jams.  On April 11, 2014, an employee, while clearing the press table due to a jam, was exposed to uncontrolled hazardous pneumatic energy that resulted in a crush injury to the hand.  b.)  The Timken Company located at 2325 E. Mansfield Rd. Bucyrus, OH 44820; On or about June 3, 2014, the employer did not ensure that energy isolating devices needed to control hazardous energy of the 5 Line assembly area were operated while employees entered the line's cell to perform tasks associated with rebuilding nest assemblies.  Employees that entered the hazard cell were exposed to caught-by and struck-by hazards inside the cell in that the equipment was not deenergized.