Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: DAL-TILE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAL-TILE CORPORATION in 834 RICKWOOD ROAD, FLORENCE, AL 35630 (NAICS 327122). OSHA activity number 339806465.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dal-Tile Corporation for free Get an email when a new federal OSHA severe-injury report for Dal-Tile Corporation is published. One employer, no account, unsubscribe in one click.
Site address
834 RICKWOOD ROAD
City
FLORENCE
State
AL
ZIP
35630
Mailing
834 RICKWOOD ROAD, FLORENCE, AL 35630
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327122
Employees
197
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 21, 2014
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a)  On or about 06/04/14 - Saw Line, employees did not utilize energy control procedures when making tile adjustments at the rectifier machine.
Recent events (1)
  • · Z (S) $6300

1910.147 C07 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 21, 2014
Abate by
Nov 7, 2014
Penalty
Initial $4,500 · Current $4,500
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  (a)  On or about 06/04/14 - Dal-Tile Corporation, employees were not trained in the hazards associated with the energy control program.
Recent events (1)
  • · Z (S) $4500

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 21, 2014
Penalty
Initial $6,300 · Current $6,300
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle:  On or about 06/4/14 - Rectifier, guarding was not provided to prevent employee(s) from having any part of their body in the danger zone during operation.
Recent events (1)
  • · Z (S) $6300

View Dal-Tile Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339806465.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.