Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OVERHEAD DOOR COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OVERHEAD DOOR COMPANY in 333 S. LAURA ST, WICHITA, KS 67201 (NAICS 444110). OSHA activity number 339807109.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Overhead Door Company — free Get an email when a new federal OSHA severe-injury report for Overhead Door Company is published. One employer, no account, unsubscribe in one click.
Site address
333 S. LAURA ST
City
WICHITA
State
KS
ZIP
67201
Mailing
P.O. BOX 305, WICHITA, KS 67211
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444110
Employees
41
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Other-than-serious 2 instances 1 exposed
Issued
Aug 26, 2014
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    In the Window Shop, inadequate housekeeping led to obstructed aisles, insufficient space to maneuver stock, and excessive levels of explosive wood dust, exposing employees to tripping hazards and explosions.
Recent events (2)
  • — I (O) $1190
  • — Z (S) $2380

1910.23 A01

Other-than-serious 1 instance 5 exposed
Issued
Aug 26, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.23(a)(1): Every stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section on all exposed sides (except at the entrance to the stairway):    In the Residential Building, the stairway access to the overhead storage was missing railing around the stairway floor opening, exposing employees to a fall of approximately eight feet to the stairs and concrete below.
Recent events (2)
  • — I (O) $2450
  • — Z (S) $4900

1910.23 C01

Other-than-serious 1 instance 10 exposed
Issued
Aug 26, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.    In the Residential Building, the overhead storage area has an approximately 26 feet of open-sided floor, exposing employees to falls of approximately 8 feet to the concrete below.
Recent events (2)
  • — I (O) $2450
  • — Z (S) $4900

1910.24 H

Other-than-serious 1 instance 10 exposed
Issued
Aug 26, 2014
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.24(h): Handrails were not provided on at least one side of closed stairways preferably on the right side descending:    In the Residential Building, a handrail was not provided for the stairway used to access the overhead storage area, exposing employees to falls of approximately 8 feet to the landing of the stairs.
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785

1910.178 P01

Other-than-serious 1 instance 20 exposed
Issued
Aug 26, 2014
Penalty
Initial $1,517 · Current $759 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    In the shop yard, the Hyster #5 forklift had no operable horn or backup alarm, exposing employees to a struck by hazard.
Recent events (2)
  • — I (O) $758.5
  • — Z (S) $1517

1910.303 F02

Other-than-serious 1 instance 20 exposed
Issued
Aug 26, 2014
Abate by
Sep 22, 2014
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    In the Residential Building on the south wall, the circuit breaker panel had the following circuit breakers unlabeled: #5, 7, 9, 11, 13, 6, 10, 12.
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785

1910.303 G02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 26, 2014
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):     In the Window Shop, energized electrical wires, previously used to energize a light switch were uncovered, exposing employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.305 B01 II

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 26, 2014
Abate by
Sep 22, 2014
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  In the residential building on the south wall, the circuit breaker enclosure box had numerous missing blanks, exposed employees to live electrical parts and subsequent electrical shock.
Recent events (2)
  • — I (S) $892.5
  • — Z (S) $1785

1910.178 A06

Other-than-serious 1 instance 20 exposed
Issued
Aug 26, 2014
Abate by
Sep 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates or markings were not maintained in a legible condition:  In the shop yard area, the Hyster #5 forklift dataplate had excessive wear and was no longer readable.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 M05 III

Other-than-serious 1 instance 10 exposed
Issued
Aug 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(m)(5)(iii): Powered industrial truck(s), with the operator dismounted and within 25 feet of the truck still in his view, did not have the parking brake set:  In the outdoor parking area, the Hyster #5 Forklift was dismounted without the parking brake being set, exposing employees to a struck by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Overhead Door Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339807109.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.