Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VENUS WAFERS, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of VENUS WAFERS, INC in 100 RESEARCH RD STE 3 (WAREHOUSE) 75 RESEARCH RD (PLANT), HINGHAM, MA 02043 (NAICS 311991). OSHA activity number 339808081.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Venus Wafers, INC — free Get an email when a new federal OSHA severe-injury report for Venus Wafers, INC is published. One employer, no account, unsubscribe in one click.
Establishment
VENUS WAFERS, INC
Site address
100 RESEARCH RD STE 3 (WAREHOUSE) 75 RESEARCH RD (PLANT)
City
HINGHAM
State
MA
ZIP
02043
Mailing
75 RESEARCH RD, HINGHAM, MA 02043
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311991
Employees
50
Ownership type
A

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 10 3 instances 5 exposed
Issued
Nov 5, 2014
Abate by
Dec 29, 2014
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides:  Location: Packing Room:  Instance A) The elevated platforms on Baggers #1 & 2 were not equipped with a standard railing exposing employees employee's to falls of over 7 feet.  Instance B) The elevated mezzanine in the packing area is not guarded, exposing employees to falls of over 11 feet.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.151 C

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 5, 2014
Abate by
Dec 29, 2014
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Location: Warehouse:  An eye wash station was not available where employees were exposed to battery acid, while adding water to the fork lift batteries.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.212 A01

Serious Gravity 5 6 instances 3 exposed
Issued
Nov 5, 2014
Abate by
Dec 29, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks:  Location: Production:  Employees were exposed to several ingoing nip points along the cracker conveyer belt, including chain drives, pulleys and rollers.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.303 B01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 5, 2014
Abate by
Dec 29, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(b)(1): 29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees.   Location: Packaging:  One of the pendulum mounted outlet plugs was burnt and malformed exposing employees to electrical shock.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B02

Serious Gravity 5 6 instances 20 exposed
Issued
Nov 5, 2014
Abate by
Dec 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Location: Packaging:          Instance A) A receptacle box, designed for fixed installation, was wired with a black flexible cord and was not securely affixed to any surface.  Instance B) Several knots in a pendulum electrical cord forced it to bend beyond the minimum bending radius of the product.  Instance C) Several unused outlet boxes openings had missing knockouts or pushed in.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C04 I

Serious Gravity 5 6 instances 5 exposed
Issued
Nov 5, 2014
Abate by
Dec 29, 2014
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded shaft end(s) projected more than one half the diameter of the shaft:  Location: Production Department:  Several of the end shafts on the production department conveyer line projected more than half the diameter were unguarded.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

View Venus Wafers, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339808081.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.