Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M & J BUILDERS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of M & J BUILDERS, LLC in 150 MAIN STREET, TUPPER LAKE, NY 12986 (NAICS 238160). OSHA activity number 339809709.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & J Builders, LLC — free Get an email when a new federal OSHA severe-injury report for M & J Builders, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
M & J BUILDERS, LLC
Site address
150 MAIN STREET
City
TUPPER LAKE
State
NY
ZIP
12986
Mailing
7 BERKLEY AVENUE, TUPPER LAKE, NY 12986
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.451 F07

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 10, 2014
Penalty
Initial $2,400 · Current $0 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:   a) At the jobsite, on or about 5/7/14:  Employees were using a tubular welded frame scaffold where the platform was over 10 feet from ground and where the upper work platform was not fully planked.  Workers on this scaffold were not provided fall protection and the scaffold was built with mixed components that are not designed for this purpose.   b)  At the jobsite, on or about 5/7/14:  Employees were using a ladder jack scaffold, approximately 11 feet from ground, without fall protection, and without adequate access to the work platform.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2400

1926.451 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:  a) At the jobsite, on or about 5/7/14:  Employees were using a tubular welded frame scaffold to work on soffit, where the platform was over 10 feet from ground and where the upper work platform was not fully planked.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B07

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap was not at least 12 inches (30 cm) and the platforms were not nailed together or otherwise restrained to prevent movement:  a) At the jobsite, on or about 5/7/14:  Employees were using a tubular welded frame scaffold where the platform was over 10 feet from ground and where that platform extended approximately 4 inches over one support end, and where that platform was not restrained to prevent movement.    Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  a)  At the jobsite, on or about 5/7/14:  Employees were using a ladder jack scaffold, approximately 11 feet from ground, without fall protection, and where the work platform was mounted outside the ladders, causing employees to climb over the pick.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 10, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a) At the jobsite, on or about 5/7/14:  Employees were using a tubular welded frame scaffold where the platform was over 10 feet from ground and where the upper work platform was not fully planked.  Workers on this scaffold were not provided fall protection.   b)  At the jobsite, on or about 5/7/14:  Employees were using a ladder jack scaffold, approximately 11 feet from ground, without fall protection.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Deleted Serious Gravity 1 2 instances 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards.  a) At the jobsite, on or about 5/7/14:  Employees were using a tubular welded frame scaffold where the platform was over 10 feet from ground and where the upper work platform was not fully planked.  Workers on this scaffold were not provided fall protection and the scaffold was built with mixed components that are not designed for this purpose.  The scaffold was built with the work platform in close proximity to a power connection to the building and employees were not trained to recognize or minimize those hazards.     b)  At the jobsite, on or about 5/7/14:  Employees were using a ladder jack scaffold, approximately 11 feet from ground, without fall protection, without adequate access to the work platform, and employees were not trained to recognize or minimize those hazards.         Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jun 25, 2014
Abate by
Jul 10, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) At the jobsite, on or about 5/7/14:  Employees were working on a multi pitched residential roof; 8:12 and 2;12, with an approximate 12 foot ground to eave height, without fall protection.     Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

View M & J Builders, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339809709.