LAREDO, TX —
OSHA Inspection: MODERN MACHINE SHOP, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MODERN MACHINE SHOP, INC. in 2000 BLAIN ST, LAREDO, TX 78044 (NAICS 332710). OSHA activity number 339811846.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MODERN MACHINE SHOP, INC.
- Site address
- 2000 BLAIN ST
- City
- LAREDO
- State
- TX
- ZIP
- 78044
- Mailing
- PO BOX 1969, LAREDO, TX 78044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 32
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.179 L03 III A
- Issued
- Aug 6, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $2,975 · Current $0 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(a): Crane hooks showing defects described in paragraph (j)(2)(iii) of this section were not discarded: At this location employees working with a 2-ton Bullard overhead crane which showed signs of wear and deformed components potentially exposing employees to overhead struck by hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $2975
1910.303 F02
- Issued
- Aug 6, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $2,975 · Current $1,983 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: In the machine shop, electrical panel boxes had unlabeled circuit breakers such as but not limited to: a. Southside of machine shop area near monarch lathe #5 had no labels circuit breakers. b. Center wall separating machine shop and welding area where square D knife switches were missing labels.
Recent events (2)
- — I (S) $1983
- — Z (S) $2975
1910.305 B01 II
- Issued
- Aug 6, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: At this location employees working on lathes and drills were exposed to electrical hazards due to missing knockout on electrical panels such as but not limited to: a. East side of machine shop lighting panel b. Center east side of shop all electrical panels c. Center east side of knife switch #14 d. Center east side knife switch #2 e. Center east side knife switch #12
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 II
- Issued
- Aug 6, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $2,975 · Current $1,983 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: At this location in the machine shop area equipment such as but not limited to the following had broken conduit exposing electrical wires: a. On the Westinghouse #2; The overflow of the coolant dripping on to the pump on to the broken conduit with exposed electrical wires. b. On the Turn-nado #1 lathe had a exposed conduit exposing the encased electrical wires, exposing employees to electrical hazard.
Recent events (2)
- — I (S) $1983
- — Z (S) $2975
1910.305 E01
- Issued
- Aug 6, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: At this facility in the machine shop on the south side the number #2 lathe the coolant pump motor was leaking fluid on to the pump which had exposed electrical wiring exposing employees to electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Aug 6, 2014
- Abate by
- Sep 4, 2014
- Penalty
- Initial $2,975 · Current $1,984 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: At this location employees working with machines with wiring having missing strain relief exposing employees to electrical hazard: a. In machine shop area on the turn-nado #1 b. In the center of machine shop on the WTML drill c. in the center of machine shop baldor grinder
Recent events (2)
- — I (S) $1984
- — Z (S) $2975
1910.253 B02 IV
- Issued
- Aug 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: At this location in back of welding shop filled cylinders which were not in use were missing caps.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Modern Machine Shop, INC.
View Modern Machine Shop, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339811846.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.