PHILADELPHIA, PA —
OSHA Inspection: CRISTIAN SANCHEZ
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CRISTIAN SANCHEZ in 1826 NORRIS AVENUE, PHILADELPHIA, PA 19121 (NAICS 238140). OSHA activity number 339814154.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CRISTIAN SANCHEZ
- Site address
- 1826 NORRIS AVENUE
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19121
- Mailing
- 565 E WINONA AVE, NORWOOD, PA 19074
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Jul 18, 2014
- Abate by
- Jul 26, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a). South side of structure- Employees performing stucco preparation work were exposed to fall hazards of approximately twenty (20) to thirty (30) feet without the walking working platform of the scaffold being fully planked or decked between the front uprights and guardrail supports. Observed on or about 17 JUNE 2014.
Recent events (1)
- — Z (S) $2800
1926.451 C02
- Issued
- Jul 18, 2014
- Abate by
- Jul 28, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a). South side of structure- The poles of the scaffold were placed on the soil directly without the use of a baseplate nor adequate firm foundation, and, in one instance, placed on scaffold planks above a basement window well where the poles did not reach the ground. Observed on or about 17 JUNE 2014. b). South side of structure- Employees installing wire mesh for stucco application were exposed to a scaffold collapse hazard as the tubular welded frame scaffold did not bear on base plates or a firm foundation. Observed on or about 17 JUNE 2014.
Recent events (1)
- — Z (S) $2800
1926.451 E01
- Issued
- Jul 18, 2014
- Abate by
- Jul 28, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a). South side of structure- Employees were not provided with a safe means of access and/or egress to the tubular welded frame scaffold platform from a lower level, exposing employees to a fall hazard of approximately twenty-nine (29) feet. Employees were using the side frame of the scaffold to access and/or egress the working levels. Observed on or about 17 JUNE 2014.
Recent events (1)
- — Z (S) $2800
1926.451 G01 VII
- Issued
- Jul 18, 2014
- Abate by
- Jul 26, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) South side of structure- Employees performing stucco operations from the 2nd and 3rd levels of the tubular welded frame scaffold were exposed to fall hazards of approximately twenty (20) to thirty (30) feet without the use of personal fall arrest systems or guardrail systems. Observed on or about 17JUNE2014.
Recent events (1)
- — Z (S) $2800
1926.454 A
- Issued
- Jul 18, 2014
- Abate by
- Aug 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards. a). Jobsite - Employees working on a tubular welded frame scaffold were not trained by a person qualified to recognize, control, or minimize hazards associated with tubular welded frame scaffolding. Noted on or about 17JUNE2014.
Recent events (1)
- — Z (S) $0
More inspections at Cristian Sanchez
View Cristian Sanchez's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339814154.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.